Steam Requirements

(Steam Heat Option Only)

Installation

For machines equipped with optional steam heat, install piping in accordance with approved commercial steam practices. Steam requirements are shown in the table below.

WARNING

Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched.

SW014

Note: Failure to install the supplied steam filter may void the warranty.

Cabinet Freestanding

Steam Supply Information

 

18

25

 

 

 

Steam inlet connection, in (mm)

1/2 NPT (DN15)

1/2 NPT (DN15)

 

 

 

Number of steam inlets

1

1

 

 

 

Recommended pressure, psi (bar)

30 – 80 (2.0 – 5.5)

30 – 80 (2.0 – 5.5)

 

 

 

Maximum pressure, psi (bar)

80 (5.4)

80 (5.4)

 

 

 

F232060

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

27