The input power box houses a cage clamp strip which furnishes supply output signals for the chemical injection supply pumps.

An external power source must be used to provide power to the injection system on the P voltage. External liquid supply connections are located on the rear of the machine.

To connect external supplies, use the following procedure:

1.Facing the rear of the machine, locate the 1-1/2" opening found at the upper right- hand side of the valve panel.

2.Gather external supply hoses and pull through opening.

3.Locate the 4 capped nozzles on the rear of the liquid supply dispenser and remove caps. See Figure 11.

Installation

Nozzles:

1. Detergent

2. Bleach

3. Sour

4. Soft

5. Specialty

3 & 4 2 5 1

U149ME2A

Figure 11

4.Connect hoses to nozzles by pushing each hose over nozzle lip. Hoses should fit snugly onto nozzles and then be secured with proper clamps.

F232060

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

29