Installation
Control Function Test
The machine should be cleaned after the installation is complete. A function test should then be executed on the unloaded machine:
1.Check the power supply for such characteristics as correct voltage, phase, and cycles to be certain they are correct for the machine.
2.Open manual
3.Turn on electric power.
4.Check the door interlock before starting operation:
a.Attempt to start the washer with the door open. The washer should not start with the door open.
b.Close the door without locking it and attempt to start the washer. The washer should not start with the door unlocked.
c.Close the door and start a cycle. Attempt to open the door while the cycle is in progress. The door should not open.
If the door lock and interlock are not functioning properly, call a service technician.
5.Select Cycle 01 by pressing key 0 and key 1 on the keypad. Then press the Start key.
6.Run a complete cycle, checking operation of water inlet valves, drain, and extract functions.
7.Rotation must be counterclockwise in the spin step. If rotation is not counterclockwise in the spin step, disconnect power. A qualified electrician must reverse any two leads between the AC drive and the motor. See Figure 14.
AC Drive Connections
Power Supply
Motor
Leads
Main Drive
Motor
R080IE3A
Figure 14
F232060 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 31 |