DIAGNOSTIC DISPLAY
Mode | Green LED | Red LED |
|
|
|
No Power to Board | Off | Off |
|
|
|
Normal Operation/ Power to Board | Simultaneous Slow Flash | |
|
|
|
Alternating Slow Flash | ||
|
|
|
Low Pressure Switch Fault | Off | Slow Flash |
|
|
|
Low Pressure Switch Lockout | Off | On |
|
|
|
High Pressure Switch Fault | Slow Flash | Off |
|
|
|
High Pressure Switch Lockout | On | Off |
|
|
|
Note: Because the pressure switches are monitored only when "Y1" (Input) is active, the code for pressure switch open will not be seen when "Y1" is off. Instead, the
“Normal Operation" or
When a pressure switch opens and causes a short cycle lockout, the pressure
BLOWER SPEED CHART
| Fact ory Shipped Set t ings | ||
Unit |
|
|
|
| ADJUST | HEAT | COOL |
|
|
|
|
24 | NORM | B | B |
|
|
|
|
30 | NORM | A | A |
|
|
|
|
36 | NORM | A | A |
|
|
|
|
42 | NORM | C | C |
|
|
|
|
48 | NORM | B | B |
|
|
|
|
60 | NORM | A | A |
|
|
|
|
NOTE - If any of the original wire is replaced, the same size and type wire must be used. Use copper conductor only, min. 75°C wire.
WARNING - Electric shock hazard. Unit must be grounded in accordance with national and local codes.
Line voltage field installed.
W1 & W2 can be used to stage electric heat accessory on 15 & 20kW models.
5, 7.5, & 10kW heater accessories function off W1 only.
DIAGNOSTIC
MODULE
CONNECTION MUST BE
2JUMPERED WHEN PRESSURE SWITCH IS NOT USED.
Connection Diagram
Single Phase – Variable Speed Motor
P/N