Rapier 48w Switch Removable Fan
4
1. Unpack the fan-only module.
Caution Follow correct anti-static procedures when installing a FOM.
Failure to do so could damage the FOM or the switch. If you are unsure
about correct procedures, contact your authorised distributor or reseller.
While observing Electrostatic Discharge (ESD) precautions, remove the
FOM from its packing material in an anti-static environment.
2. Remove the current fan-only module from the switch.
Using a flat screwdriver, loosen the captive screws on the faceplate of the
FOM, and slide the FOM out of its cage. The internal power connection is
quite solid so pull firmly on the captive screws.