14.Before rebooting the stand alone switch or stack, you must change the active image, including each slave switch in the stack. To check the active image for each switch use the following command.
Show bootvar
15.The resulting display will tell you which image is active on each switch. Depending on your configuration, you can now issue one of the following commands, substituting x and y from the Show bootvar command:
For a stand alone switch -
Boot sys
For each switch in a stack -
Boot sys unit x
This command will switch the active image for next reboot.
16. Reboot the device with the command:
reload
This command will cause the switch to reboot. By the end of the reboot process, the final code drop will be running.
17. Download saved configuration (if needed) to the device.
Note
In case of a stack both the interim version and the final version should be downloaded to ALL the units in the stack at the same time
Note
Following this procedure and uploading the interim code drop is required only once. Any future S/W upgrades will not require the additional upload of the interim code drop.