Installing the Bridging Converter
14
Planning the Installation
Be sure to observe the following guidelines when planning the installation of
your bridging converter.
The AT-FS238a/x and AT-FS238b/x Series Bridging Converters must
be connected back-to-back; therefore, one AT-FS238a/x and one AT-
FS238b/x Series converters are required.
The end-node connec ted to the 10Base-T/1 00Base-TX twisted pair
port can operate at either 10 Mbps or 100 Mbps.
The end-node connected to the tw isted pair port on the bridging
converter can be a network adapter card, repeater, router, hub, or
another bridging converter.
The twisted pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband amplifiers,
electrical motor, and fluorescent fixtures.
Refer to Table 3 for the cabling specifications for the twisted pair port.
Table 3 10Base-T/100Base-TX Twisted Pair Cabling Specifications
Operating Mode Cable Type Maximum Operating
Distance
10Base-T Shielded or unshielde d Category 3 or better 100 m (328 ft)
100Base-TX Shielded or unshielded Category 5 or better 100 m (328 ft)