AT-FS709FC Series Installation Guide

Make sure that the cable connected to the fiber optic receiver port on the switch is connected to the transmitter port on the remote end node and that the fiber optic transmitter port on the switch is connected to the receiver port on the end node.

Test the attenuation on the fiber cable to ensure that it does not exceed acceptable values.

Verify that you are using the appropriate type of fiber optic cabling and that you have not exceeded the allowable maximum distance. For information, refer to “Twisted Pair Cable and Fiber Optic Cable Guidelines” on page 17.

Check that the operating specifications (e.g., wavelength and maximum operating distance) of the fiber optic port on the end node are compatible with the operating specifications of the fiber optic port

Gon the Ethernet switch.

Verify that the end node connected to the fiber optic port is operating in full-duplex mode.

Note

See “Technical Specifications” on page 21 for the operating specifications of the fiber optic port on the switch.

Warranty Registration

When you have finished installing the switch, register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at www.alliedtelesyn.com/support/warrantyf.asp and completing the on-line registration.

Technical Specifications

Table 6 lists the switch specifications.

Table 2 Technical Specifications

Physical Specifications

Dimensions (H x W x D)

4.4 cm x 33.0 cm x 20.3 cm

(1.7 in x 13 in x 8.0 in)

 

 

 

Weight

2.0 kg (4.0 lbs)

 

 

Required Ventilation (all sides)

19 cm (7.5 in)

 

 