NETWORK RESILIENCY SOLUTIONS VCStack + Link aggregation
x900 Configuration
All log messages are sent to a syslog server.
Allow
A resiliency link backs up the dedicated stacking link. If the stacking link fails, communication is maintained to allow graceful reconfiguration
Use priority to
Create VLANs. VLAN 169 for servers, and VLANs
Create link aggregation groups across the VCStack members for resiliency. One for servers, and three for edge switches
log buffered level errors log host 192.168.10.11
log host 192.168.10.11 level debugging
stack resiliencylink eth0 stack 1 priority 1
vlan database
vlan
interface port1.0.1 switchport switchport mode access switchport access vlan 169
interface port2.0.1 switchport switchport mode access switchport access vlan 169
interface port1.0.3 switchport switchport mode access switchport access vlan 170
interface port2.0.3 switchport switchport mode access switchport access vlan 170
interface port1.0.5 switchport switchport mode access switchport access vlan 171