NETWORK RESILIENCY SOLUTIONS VCStack + Link aggregation

Create link aggregation groups across the VCStack members for resiliency. One for servers, and three for edge switches

Assign an IP address to each VLAN. Configure DHCP relay to forward DHCP requests to the server

Configure a default route to external networks

Configure NTP (Network Time Protocol) with the IP address of the NTP server

interface port2.0.5 switchport switchport mode access switchport access vlan 171 static-channel-group 3

interface port1.0.7 switchport switchport mode access switchport access vlan 172 static-channel-group 4

interface port2.0.7 switchport switchport mode access switchport access vlan 172 static-channel-group 4

interface vlan169

ip address 192.168.169.1/24

interface vlan170

ip address 192.168.170.1/24

ip dhcp-relay server-address 192.168.169.254

interface vlan171

ip address 192.168.171.1/24

ip dhcp-relay server-address 192.168.169.254

interface vlan172

ip address 192.168.172.1/24

ip dhcp-relay server-address 192.168.169.254

ip route 0.0.0.0/0 192.168.169.254

ntp server 192.168.10.11

end