DISTRIBUTION AMPLIFIERS

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your DA1912SX Distribution Amplifier. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your DA1912SX and to prevent fire and shock hazard. Please read them carefully and heed all warnings.

1.1 GENERAL

Unauthorized personnel shall not open the unit since there are high-voltage components inside.

Qualified Altinex service personnel, or their authorized representatives must perform all service.

1.2SAFETY GUIDELINES FOR THE RACK- MOUNTING OF THE DA1912SX

Maximum operating ambient temperature is 35 (degrees C).

Never restrict the airflow through the device’s fan or vents.

When installing equipment into a rack, distribute the units evenly. Otherwise, hazardous conditions may be created by an uneven weight distribution.

Connect the unit to a properly rated supply circuit.

Reliable Earthing (Grounding) of Rack-Mounted Equipment should be maintained.

1.3 INSTALLATION

For best results, place the DA1912SX Distribution Amplifier on a flat, level surface in a dry area away from dust and moisture.

To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the DA1912SX Distribution Amplifier in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.

Handle the DA1912SX Distribution Amplifier carefully. Dropping or jarring can damage internal components.

Do not place heavy objects on top of the DA1912SX. If the DA1912SX is to be

2

mounted, to a table or wall, use only Altinex made mounting accessories, such as mini mount-brackets (DA1295FC) and cables for optimum setup.

To turn off the main power, be sure to remove the cord from power outlet. The power outlet socket should be installed as near to the equipment as possible, and should be easily accessible.

Do not pull power cord or any cable that is attached to the DA1912SX Distribution Amplifier.

If the DA1912SX Distribution Amplifier is not used for an extended, disconnect the power cord from the power outlet.

1.4 CLEANING

Unplug the DA1912SX power cord before cleaning. Clean surfaces with a dry cloth. Never use strong detergents or solvents such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.

1.5 FCC / CE NOTICE

This device complies with the part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

2

Page 3
Image 3
Altinex DA1912SX manual Precautions / Safety Warnings

DA1912SX specifications

The Altinex DA1912SX is a versatile and robust audio-visual distribution amplifier, designed to meet the demands of modern AV systems in commercial and residential environments. This device enhances signal integrity and ensures optimal distribution of video signals across multiple outputs, making it an essential component in complex AV setups.

One of the primary features of the DA1912SX is its ability to support a wide range of video formats. It handles both standard and high-definition video signals, including 1080p, and can accommodate various input sources such as HDMI and component video. This flexibility makes it an ideal choice for both traditional and cutting-edge AV installations.

The DA1912SX offers 1 input and 12 outputs, allowing users to effectively distribute a single source signal to multiple display devices. This capability is particularly beneficial in situations like conference rooms, classrooms, and auditoriums where multiple screens may be needed to ensure visibility for a large audience. With its high bandwidth capacity, the DA1912SX minimizes signal degradation and ensures that quality remains consistent across all output channels.

In terms of technical characteristics, the DA1912SX incorporates advanced signal processing technology that boosts weak signals without introducing noise. This is essential for maintaining the integrity of the audio and video output over long cable runs. The unit is designed to support EDID management, allowing for seamless communication between sources and displays, which optimizes the video resolution and minimizes compatibility issues.

Another noteworthy aspect of the Altinex DA1912SX is its user-friendly interface. It features GPIO (General Purpose Input/Output) capabilities for integrating with external control systems, enabling users to automate their AV setups effortlessly. The sleek and compact design of the device allows for easy installation in racks or on tables, demonstrating its adaptability in various environments.

Additionally, the DA1912SX includes comprehensive status indicators and diagnostic features. This ensures that users can quickly troubleshoot any issues that may arise, thus enhancing overall system reliability.

In summary, the Altinex DA1912SX audio-visual distribution amplifier is engineered for high performance and reliability, making it a go-to solution for professionals seeking to deliver superior audio-visual experiences. Its robust features, extensive compatibility, and ease of integration position it as an invaluable tool in any advanced AV system.