MULTI-TASKER™

Example:

One MT104-108card is in slot #2 of unit 3: Send the command [VERC2U3] and the Multi-Tasker™ Enclosure will return:

MT104-108 690-0160-002

MT104-108 = card type

690-0160-002= software version

2.[C]

This command receives the status of the card.

Command Format: [CnUi]

Cn = card ID (n = # from 1 to max slots)

Ui = unit ID (i = from 0 to 9) ( refer to the MT100-100 user’s guide for explanation)

[ONmCnUiS]: for a SINGLE card

This command enables input “m” and disables all other inputs.

[ONmCnUi]: enables input

Default when plugged in = Input 1 is ON

m = Input number (m = 1 to 7, 7 is internal)

Cn

= Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID number (i = 0 to 9)

S

= saves command to memory

Example:

If all of the inputs on the MT104-108card are OFF and the card is in slot #5 of unit 3:

1) [ON1C5U3]: Turns ON input 1.

Example:

An MT104-108input 1 is ON. will yield the Multi-Tasker™:

ON: 1 C02

card is in slot #2 of unit 3 and Sending the command [C2U3] following feedback from the

2) [ON3C5U3]: Turns ON input 3 (input 1 is

now OFF).

[ONmGkUiS]: for a GROUP of cards

This command enables input "m" for each card in group "k" of unit "i".

[ONmGkUi]: enables a group of inputs

ON: 1= input 1 is ON

C02 = card is in slot 2

If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback.

3.[CnS]

This command saves the current status of the card's input selection configuration. This configuration will be restored after system is reset or powered off then on.

Cn

= card number

S

= save configuration

If Inputs 1,2,3,4,5 and 6 are enabled, the feedback after sending the command [C4S], for slot 4, would be:

ON:1,2,3,4,5,6 C04 Saved

4.[ON]

This command enables one input of a single card or a group of cards.

m

= Input (m = 1 to 7, input 7 is internal)

Gk

= group number (k = # from 1-9)

Ui

= unit number (i = # from 0-9)

S

=saves command to memory

Example:

[ON1G1U1]: Turns ON input 1 for each card in group 1 of unit 1.

[ON…..P]: sets path

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded and then all switched at the same time.

Command Format: [ONmCnUiP]

m

= Input number (m = 1 to 7, 7 is internal)

Cn

= card ID (n = slot # from 1 to max slots)

Ui

= Unit ID number (i = 0 to 9)

P

= path

7

Page 8
Image 8
Altinex MT104-108 manual Command Format CnUi, ONmCnUiS for a Single card, On 1 C02, ONmGkUiS for a Group of cards, CnS