MULTI-TASKER

Ix = select input x (x is # from 1 to 16)

Oy = connect to output y (y is # from 1 to 8)

Cn = card ID number (n is # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

Ui = unit ID, i is # from 0 to 9). (Refer to MT100- 100 user’s guide to set Unit ID).

S = saves command to memory

Example:

To connect input 4 to output 2 (card 2 of unit 3), use the [I4O2C2U3] command.

[ImO*…]. This command connect input m to all outputs.

4. [ON]

This command enables one or more outputs of a single card or a group of cards

[ONmCnUiS]: for a single card

This command enables output “m” without affecting any other outputs.

Default when plugged in = ALL OFF

m = Output number (m = 1 to 8)

n = Card ID number (n = 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

i = Unit ID number (i = 0 to 9)

S = saves command to memory

Example:

1)[ON12C5U3]: Turns ON only output 1 and 2 of the MT105-110/(111)card located in slot #5 of the MT100-100 Enclosure with unit ID3.

2)[ON3C5U3]: Turns ON only output 3 of the MT105-110/(111) card located in slot #5 of the MT100-100 Enclosure with unit ID3.

After the [ON12C5U3] and [ON3C5U3] commands have been executed, output 1, 2 and 3 will be ON.

3)[ONC5U3]: Turns ON all outputs of the card.

[ONmGkUiS]: for a group of cards

This command enables output "m" for each card in group "k" of unit "i".

m = card output (m = # from 1-8)

k = group number (k = # from 1-9)

i = unit number (i = # from 0-9)

S = saves command to memory

Example:

1.[ON1G5U1]: Turns ON output 1 for each card in group5 of unit 1.

2.[ONG5U1]: Turns ON all outputs for each card in group5 of unit 1.

[ON…..P]: sets path

This command will set the path for the output, but it is not active until the switch command is executed ( [SW] ). Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded.

Command Format: [ONmCnUiP]

m = Output number (m =1 to 8)

n = card ID No. (n = a slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

P = path

Example:

If 2 cards are at slot 6 and 7 of unit 3:

To enable output 1 and 2 of card 6 and output 3 and 4 of card 7 simultaneously, use the following commands:

[ON12C6U3P]

[ON34C7U3P]

[SW]

If "F" is included use the [ONmCnUiPF] command or the [ONmCnUiFP] command.

10

10

Page 10
Image 10
Altinex 400-0226-003, MT105-111, MT105-110 manual ONmCnUiS for a single card, ONmGkUiS for a group of cards, ON…..P sets path