INSTALLING YOUR MT107-301/305/306 6

MULTI-TASKER™

INSTALLING YOUR MT107-301/305/306 6

Step 1. Locate the MT107-100currently installed in the Multi-Tasker™. Ensure there are enough empty slots in the enclosure to allow for the one or more MT107-301/305/306's to be installed.

Step 2. Route the ribbon cables through the notch in the add-on boards and connect to the MT107-100base assembly using special high bandwidth cables provided with the Engine. Make sure that cable connector is secured in the socket of the input card.

Step 3. Carefully, slide the MT107-301/305/306 into slot of the Multi-Tasker™ Enclosure.

Step 4. Secure each card by tightening the retainer screws at the top and bottom of each card.

OPERATION

7

7.1 RS-232 CONTROL

The MT107-301/305/306has many advanced remote control capabilities when used in the Multi-Tasker™ Enclosure as part of an MT107-100Matrix Switcher. These capabilities are accessible through standard RS-232 communication. The actual controlling can be accomplished through a computer control system or any other device capable of sending RS-232 commands.

7.2 DESCRIPTION OF COMMANDS

Please, see the MT107-100User's Guide for a full listing of commands available for the MT107 301/305/306 as part of a Multi-Tasker™ Matrix Switcher.

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MT107-301/305/306.However, we would like to offer suggestions for the following:

8.1 BAD SIGNAL

Cause 1: The display is connected to the wrong card.

Solution: Make sure the video signals are coming from the video card (-305) and sync signals are coming from the sync card (-306). If the signal is still bad, see Cause 2.

Cause 2: The switch settings are wrong.

Solution: If the output card is an MT107-301, make sure the Video/Sync switch settings are in the correct position for the signal type on each channel. If the signal is still bad, call Altinex at (714) 990-2300.

9