TROUBLESHOOTING CHART

TROUBLESHOOTING CHART

PROBLEM

CAUSE

SOLUTION

No Power, Nothing

Is the cord plugged in.

Plug in cord.

Circuit breaker tripped in building.

Reset breaker.

Runs

Faulty switch.

Call for service.

 

 

Faulty power cord or pigtail.

Call for service.

Vacuum Motor Will Not

Vacuum circuit breaker tripped.

Reset breaker.

Run

.Faulty main vacuum switch.

Call for service.

 

Loose wiring.

Call for service.

 

Faulty vac motor.

Call for service.

 

Debris lodged in vac shoe.

Remove debris from vac shoe.

Vacuum Motor Runs

 

 

But

.Dome gasket defective or missing.

Replace as necessary.

Suction Is Poor

Vacuum hose cracked or hose cuff loose.

Replace or repair as necessary.

 

Recovery tank full / float ball stuck in the

Turn off vac motor. Drain and rinse

 

up position.

recovery tank.

Poor Or No Water Flow

Main pump switch off.

Turn on.

(Carpet Is Streaky)

 

 

 

Jets clogged or missing.

Clean using a vinegar /water solution or

 

 

replace.

 

Solution filter clogged.

Drain solution tank and clean solution

 

 

filter.

 

Faulty solenoid.

Call for service.

Brush Does Not Spin

Brush switch off.

Turn on brush switch.

Brush circuit breaker tripped.

Reset circuit breaker.

 

 

Brush belt broken.

Replace as necessary.

 

Faulty brush motor.

Call for service.

4-7