Windsor CDT7, 10080220 manual Only Qualified Warning: Maintenance Personnel Are

Models: CDT7 10080220

1 42
Download 42 pages 44.19 Kb
Page 21
Image 21
ONLY QUALIFIED

ONLY QUALIFIED

! WARNING: MAINTENANCE

PERSONNEL ARE

TO PERFORM THE FOLLOWING REPAIRS.

BELT REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank and brush.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt.

5.Remove the (2) screws that fasten the vacuum shoe links (p/n 05016) to the brush housing.

6.Remove the (3) screws that fasten the side plate (p/n 62759) to the brush housing to remove belt. NOTE: All components associated with driving the brush will come out with the side plate.

7.Reverse process to install belt.

86249420

PRV NO. 62759

86227350

PRV NO. 05016

CADET 86038220 03/16/07