Altinex MX2106AV manual Troubleshooting Guide, Switcher

Models: MX2106AV

1 10
Download 10 pages 36.66 Kb
Page 9
Image 9
TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MX2106AV unit. However, we would like to offer the following suggestions:

8.1 LEDs ARE OFF

Cause 1: The power adapter is installed wrong.

Solution 1: Make sure the adapter output is connected to the POWER input jack on the unit. If one of the LEDs is still not on, see Solution 2.

Solution 2: Ensure the adapter is plugged into an AC outlet that has power. If the adapter has AC power and the LEDs are still off, see Cause 2.

Cause 2: The wrong power adapter is installed.

Solution 1: Please use the Altinex supplied external adapter (9V, 500mA). If one of the LEDs is still not on, please call ALTINEX at (714) 990-2300.

8.2 UNIT DOES NOT AUTO-SWITCH

Cause 1: The manual override switch is installed.

Solution: Remove the connection to the INPUT SELECT jack on the unit. If a plug is installed in the jack, even without a switch, the unit will not auto-switch properly. If the unit does not auto-switch with the plug removed, see Cause 2.

Cause 2: The signal is not active or is improperly formatted.

Solution 1: Remove the input signals from the switcher. If the IN 2 LED is OFF, call ALTINEX at (714) 990-2300. If the IN 2 LED is ON, see Solution 2.

Solution 2: Connect a properly formatted VGA type signal from to INPUT 1. If the switcher does not switch to INPUT 1, see Solution 3.

SWITCHER

Solution 3: Bypass the switcher and connect the output of the source directly to the display. If the display is good, then call ALTINEX at (714) 990-2300.

8.3 NO DISPLAY

Cause 1: The source has a problem.

Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2.

Cause 2: Manual override is ON.

Solution: Make sure there is nothing connected to the INPUT SELECT port on the switcher. If there is nothing connected, see Cause 3.

Cause 3: Signal is bad or missing.

Solution 1: Make sure the switcher output is connected to the monitor. If there is still no display, see Solution 2.

Solution 2: Remove both inputs to the switcher and connect the active signal form the source to INPUT 2. If there is still no display, see Solution 3.

Solution 3: Bypass the switcher and connect the output of the source directly to the monitor. If the display is good, then call ALTINEX at (714) 990-2300. If there is still no display, see Cause 4.

Cause 4: Cable connections are incorrect.

Solution: Make sure the cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 5.

Cause 5: The display has a problem.

Solution: Make sure the display has power and is turned ON. If there is still no display, please call Altinex at (714) 990-2300.