SPECIAL APPLICATION
400-0384-003 25
Command Format: [SETMD=xCi]
x= Time Delay (x =# from 01 to 99)
01 = 0.1 minutes (6 sec)
02 = 0.2 minutes (12 sec)
99 = 9.9 minutes
Ci = Unit ID (i = # from 1 to 99)
Example:
Set the time delay to a value of one minute by
sending the command [SETTMD=10]. Use the
[RDMD] command to read values and check
settings.
62. [MDTYPE]
This command sets the motion detector’s time
delay. The sensor will trigger until a target is
found and then stop sensing and not check for a
new target until after the specified delay time.
The range is 01 to 99, where each increment is
0.1 minutes and the minimum delay time is
6seconds.
Command Format: [MDTYPE=xCi]
x= Sensor Type (x =0 or 1)
0 = Ultrasound Motion Detector
1 = PIR Motion Detector
Ci = Unit ID (i = # from 1 to 99)
Example:
Set the time delay to a value of one minute by
sending the command [SETTMD=10]. Use the
[RDMD] command to read values and check
settings.
63. [RDMD]
Use this command to display the motion
detector’s settings and check its status. The
status includes the settings, assigned
subroutines, current detected reading,and
whether or not the motion detector is active.
Command Format: [RDMDCi]
Ci = Unit ID (i = # from 1 to 99)
Example:
The motion detector’s trigger level is set to 1.0V.
Subroutine 10 is assigned for objects moving
away from the detector, and subroutine 11 is
assigned for objects moving toward the detector.
Send the command [RDMD] and receive
feedback similar to the following:
Motion Detector ON
MD Current value:04
MD Threshold value:10
MD0=SUB10
MD1=SUB11
ID COMMANDS RSI, SIDn, SIDnCi, RSN
64. [RSI]
This command resets the card IDs in the
system. After sending this command, each card
ID will be ‘0’.
Command Format: [RSI]
Example:
Send the command [RSI] to the system with
ID 2. The card can no longer be recognized as
ID 2, it will be ID 0.
REMEMBER: A command sent without the unit
ID will be executed by all the
PE1005s connected to the
RS-232 port.
65. [SIDn]
This command sets the ID number of all cards
connected to the RS-232 bus to the same value.
The default unit ID is zero.
Command Format: [SIDn]
n= New ID (n = # from 1 to 99)
Example:
Send the command [SID1] to the system. The
card ID is now one, and “C1” must be included
at the end of each command line, as in
“[VERC1]”, for only the unit with ID1 to respond.