Alto-Shaam HFT2SYS-300, HFT2-400 DANGeR, electric a l connection, D A N G e R, ins ta l l at io n

Models: HFT2SYS-300 HFT2SYS-500 HFT2-500 HFT2SYS-400 HFT2-300 HFT2-400

1 26
Download 26 pages 60.65 Kb
Page 11
Image 11
electric a l connection

ins ta l l at io n

electric a l connection

The appliance must be installed by a qualified service technician. The oven must be properly grounded in accordance with the National Electrical Code and applicable local codes.

D A N G e R

to avoid electrical shock, this appliance mUSt be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the national electrical Code anSi/ nFpa no. 70. in Canada, all electrical connections are to be made in accordance with CSa C22.1, Canadian electrical Code part 1 or local codes.

Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “off” position.

Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes.

ELECTRICAL - HFT2-300

voltage

phase

cycle/hz

amps

kW

cord & plug

208-240 (agcy) 1

60

13.6

3.3

NEMA 6-15P

at 208

1

60

11.8

2.5

15A - 250V Plug

at 240

1

60

13.6

3.3

 

230

1

50

13.0

3.0

cee 7/7,

 

 

 

 

 

220-230v plug

ELECTRICAL - HFT2-400

 

 

voltage

phase

cycle/hz

amps

kW

cord & plug

208-240 (agcy) 1

60

13.7

3.3

NEMA 6-20P

at 208

1

60

11.9

2.5

20A - 250V Plug

at 240

1

60

13.7

3.3

 

230

1

50

13.1

3.0

cee 7/7,

 

 

 

 

 

220-230v plug

 DANGeR DANGeR

eleCtRiCal COnneCtiOnS mUSt be made bY a QUaliFied SeRviCe teCHniCian in aCCORdanCe WitH appliCable eleCtRiCal COdeS.

enSURe pOWeR SOURCe matCHeS vOltage Stamped On applianCe nameplate. DANGeR

enSURe pOWeR SOURCe matCHeS vOltage Stamped On applianCe nameplate.

REGARDING INTERNATIONAL STANDARD UNITS:

If the unit is not equipped with flexible cord with plug, an all-pole country approved disconnection device which has a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring for disconnection. When using a cord without a plug, the green/yellow conductor shall be connected to the terminal which is marked with the ground symbol. If a plug is used, the socket outlet must be easily accessible. If the power cord needs replacement, use a similar one obtained from the distributor.

For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked Manual background

with the following symbol.

ELECTRICAL - HFT2-500

voltage phase cycle/hz amps kW

cord & plug

208-240 (agcy) 1

60

15.7

3.8

at 208

1

60

13.6

2.8

at 240

1

60

15.7

3.8

NEMA 6-20P

20A - 250V Plug

230 1 50 15.0 3.5 cee 7/7,

220-230v plug

Wire diagrams are included in the literature

package supplied with the unit..