ins ta l l at io n
electric a l connection
The appliance must be installed by a qualified service technician. The oven must be properly grounded in accordance with the National Electrical Code and applicable local codes.
D A N G e R
to avoid electrical shock, this appliance mUSt be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the national electrical Code anSi/ nFpa no. 70. in Canada, all electrical connections are to be made in accordance with CSa C22.1, Canadian electrical Code part 1 or local codes.
Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “off” position.
Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes.
ELECTRICAL -
voltage | phase | cycle/hz | amps | kW | cord & plug |
60 | 13.6 | 3.3 | NEMA | ||
at 208 | 1 | 60 | 11.8 | 2.5 | 15A - 250V Plug |
at 240 | 1 | 60 | 13.6 | 3.3 |
|
230 | 1 | 50 | 13.0 | 3.0 | cee 7/7, |
|
|
|
|
| |
ELECTRICAL - |
|
| |||
voltage | phase | cycle/hz | amps | kW | cord & plug |
60 | 13.7 | 3.3 | NEMA | ||
at 208 | 1 | 60 | 11.9 | 2.5 | 20A - 250V Plug |
at 240 | 1 | 60 | 13.7 | 3.3 |
|
230 | 1 | 50 | 13.1 | 3.0 | cee 7/7, |
|
|
|
|
|
DANGeR
eleCtRiCal COnneCtiOnS mUSt be made bY a QUaliFied SeRviCe teCHniCian in aCCORdanCe WitH appliCable eleCtRiCal COdeS.
DANGeR
enSURe pOWeR SOURCe matCHeS vOltage Stamped On applianCe nameplate.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with plug, an
For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an
with the following symbol.
ELECTRICAL -
voltage phase cycle/hz amps kW | cord & plug |
60 | 15.7 | 3.8 | ||
at 208 | 1 | 60 | 13.6 | 2.8 |
at 240 | 1 | 60 | 15.7 | 3.8 |
NEMA
20A - 250V Plug
230 1 50 15.0 3.5 cee 7/7,
Wire diagrams are included in the literature
package supplied with the unit..
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 9..