QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 11.
SUb TITle
TITle
elecTrIcal
InSTallaTIon

This appliance must be branch circuit protected with

proper ampacities, in accordance with the wiring

diagram. The Quickchiller must be properly grounded

in accordance with the National Electrical Code

and applicable local codes. Wire size for the main

incoming power to the unit must match the minimum

size listed in the specifications applicable to the

specific Quickchiller model. For supply connections,

locate the wire size listed in this manual.

Before operating the chiller, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.

noTe: after electrical connections have been

completed, operate the appliance in any

chilling mode for a period of 15 minutes

and recheck the main power connections

at the terminal block to make certain they

remain tight.

danger

To avoid electrical shock, this

appliance MUST be adequately

grounded in accordance with local

electrical codes or, in the absence of

local codes, with the current edition

of the National Electrical Code ANSI/

NFPA No. 70. In Canada, all electrical

connections are to be made in

accordance with CSA C22.1, Canadian

Electrical Code Part 1 or local codes.

danger

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

voltag e phase cycle/hz Qc2-3 Qc2-20 Qc2-40 Qc2-100
Self-conTaIneD
115V 1 ph 60 Hz
reCoMMeNded CirCuit aMper age:
plug CoNfiguratioN:
16A, 1.84kW
20 amps
NEMA 5-20P
16A, 1.8kW
20 amps
NEMA 5-20P
Not avail able Not available
Self-conTaIneD
115/208-230 1 ph 60 Hz
reCoMMeNded CirCuit aMper age:
plug CoNfiguratioN:
Not avail able Not available
16A, 3.8kW
20 amps
NEMA 14-20P
Not available
Self-conTaIneD
115/208-230 1 ph 60 Hz
reCoMMeNded CirCuit aMper age:
reCoMMeNded wire size:
Not avail able Not avail able Not available
24A, 5.76kW
30 amps
4 wire direct
Self-conTaIneD
115/208-230 3 ph 60 Hz
reCoMMeNded CirCuit aMper age:
reCoMMeNded wire size:
Not avail able Not avail able Not available
16A, 6.64kW
20 amps
5 wire direct
reMoTe coMpreSSor
(cabinet only)
208-240VAC 1 ph 50/60 Hz
reCoMMeNded CirCuit aMper age:
reCoMMeNded wire size:
Not avail able Not avail able Not available contact
factory
elecTrIcal SpecIfIcaTIonS
Wire diagrams are located near the top of the
unit, close to the compressor or control panel.