QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 11.
SUb TITle
TITle
elecTrIcalInSTallaTIon
This appliance must be branch circuit protected with
proper ampacities, in accordance with the wiring
diagram. The Quickchiller must be properly grounded
in accordance with the National Electrical Code
and applicable local codes. Wire size for the main
incoming power to the unit must match the minimum
size listed in the specifications applicable to the
specific Quickchiller model. For supply connections,
locate the wire size listed in this manual.
Before operating the chiller, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
noTe: after electrical connections have been
completed, operate the appliance in any
chilling mode for a period of 15 minutes
and recheck the main power connections
at the terminal block to make certain they
remain tight.
danger
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
danger
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
voltag e phase cycle/hz Qc2-3 Qc2-20 Qc2-40 Qc2-100
Self-conTaIneD
115V 1 ph 60 Hz
reCoMMeNded CirCuit aMper age:
plug CoNfiguratioN:
16A, 1.84kW
20 amps
NEMA 5-20P
16A, 1.8kW
20 amps
NEMA 5-20P
Not avail able Not available
Self-conTaIneD
115/208-230 1 ph 60 Hz
reCoMMeNded CirCuit aMper age:
plug CoNfiguratioN:
Not avail able Not available
16A, 3.8kW
20 amps
NEMA 14-20P
Not available
Self-conTaIneD
115/208-230 1 ph 60 Hz
reCoMMeNded CirCuit aMper age:
reCoMMeNded wire size:
Not avail able Not avail able Not available
24A, 5.76kW
30 amps
4 wire direct
Self-conTaIneD
115/208-230 3 ph 60 Hz
reCoMMeNded CirCuit aMper age:
reCoMMeNded wire size:
Not avail able Not avail able Not available
16A, 6.64kW
20 amps
5 wire direct
reMoTe coMpreSSor
(cabinet only)
208-240VAC 1 ph 50/60 Hz
reCoMMeNded CirCuit aMper age:
reCoMMeNded wire size:
Not avail able Not avail able Not available contact
factory
elecTrIcal SpecIfIcaTIonSWire diagrams are located near the top of the
unit, close to the compressor or control panel.