QUI CK CH IL L ER • M N- 29 64 7 ( RE V. 0 ) • I NS TA LL AT I ON /O PE RA TI ON /S ER VI C E MA NU AL • 12.
SUB TITle
TITle
elecTrIcal
InSTallaTIon

This appliance must be branch circuit protected with

proper ampacities, in accordance with the wiring

diagram. The Quickchiller must be properly grounded

in accordance with the National Electrical Code

and applicable local codes. Wire size for the main

incoming power to the unit must match the minimum

size listed in the specifications applicable to the

specific Quickchiller model. For supply connections,

locate the wire size listed in this manual.

Before operating the chiller, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.

noTe: after electrical connections have been

completed, operate the appliance in any

chilling mode for a period of 15 minutes

and recheck the main power connections

at the terminal block to make certain they

remain tight.

danger

To avoid electrical shock, this

appliance MUST be adequately

grounded in accordance with local

electrical codes or, in the absence of

local codes, with the current edition

of the National Electrical Code ANSI/

NFPA No. 70. In Canada, all electrical

connections are to be made in

accordance with CSA C22.1, Canadian

Electrical Code Part 1 or local codes.

danger

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

voltag e phase cycle /hz Qc2-3 Qc2-20 Qc2-40 Qc2-100 Qc2-100r
remote
115 1 ph 60 Hz
recom mended circuit amper age:
plug c onfig uratio n:
16A, 1.8kW
20 amps
NEMA 5-20P
16A, 1.8kW
20 amps
NEMA 5-20P
not av ailabl e not av ailabl e not available
115/208-230 1 ph 60 Hz
recom mended circuit amper age:
plug configuration:
not av ailabl e not available
16A, 3.7kW
20 amps
NEMA 14-20P
24A, 5.5kW
30 amps
4 wire direct
20A, 4.6kW
30 amps
4 wire direct
115/208-230 3 ph 60 Hz
recom mended circuit amper age:
recom mended wire size:
not av ailabl e not av ailabl e not available
16A, 3.7kW
20 amps
5 wire direct
not available
220 1 ph 50 Hz
recom mended circuit amper age:
recom mended wire size:
not available
14A, 1.8kW
20 amps
3 wire direct
20A, 4.4kW
30 amps
5 wire direct
20A, 4.4kW
30 amps
3 wire direct
16A, 3.5kW
20 amps
3 wire direct
380-420 3 ph 50 Hz
recom mended circuit amper age:
recom mended wire size:
not av ailabl e not available
10A, 3.8kW
20 amps
5 wire direct
12A, 4.6kW
20 amps
5 wire direct
7A, 2.7kW
15 amps
5 wire direct
elecTrIcal SpecIfIcaTIonS
Wire diagrams are located near the top of the
unit, close to the compressor or control panel.