SITe InSTallaTIon
InSTallaTIon
Qc2-100 Bottom View
WaTer DraInage
A 1" NPS drain is located under the QC2-100. Connect
the drain pipe using Teflon tape to discharge through
an indirect waste pipe into an open-site drain by
means of a 2" (51mm) air gap. Connection must be
within 10' (3m) of the unit.
noTe: In the U.S.A., this equipment is to be installed
to comply with the Basic Plumbing Code of the
Building Officials and Co de Administrators
International, Inc. [BOCA], and the Food
Service Sanitation Manual of the Food & Drug
Administration [FDA].
15-1/2" (394mm)
Hinged Left
35-1/2" (902mm)
Hinged Right
17-5/8" (447mm)
Front
Back
LeftRight
DraInage
Qc2-3 Qc2-20 Qc2-40
Evaporator pan: no InstallatIon rEqUIrEd
Qc2-100
onE (1) Floor draIn:
1/2" (12,7mm) dIamEtEr
Drain