QUI CK CH IL L ER • M N- 29 64 7 ( RE V. 0 ) • I NS TA LL AT I ON /O PE RA TI ON /S ER VI C E MA NU AL • 3.
clearance reQUIreMenTS
18" (457mm) mi nimum c leara nce
from h eat pr oducin g equip ment.
InSTallaTIon reQUIreMenTS

Unit should not be tipped on its side.

If tipped, unit must stand in the

upright position for a mInImUm of 12

hours before operating. tipping will

cause damage to the unit and void the

warranty if not allowed to "rest".
Appliance must be installed level.
The appliance must not be installed in any area
where it may be affected by steam, grease, dripping
water, extreme temperatures, or any other severely
adverse conditions.
In order to maintain standards established by the
National Sanitation Foundation, all counter mounted
equipment must use legs that allow for a 4" (102mm)
clearance between the cabinet and the counter.
caution

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

5-Year Limited
Warranty on
self-contained
compressor
Effective from date of
shipment. (exclu des labor)
Position the Quickchiller
to allow sufficient air
ventilation through the
condensing unit(s).
Avoid installing the
chiller immediately
adjacent to fryers,
charbroilers, or any other
equipment producing
grease laden air; heat
producing equipment
such as ovens and ranges;
and steam discharging
equipment such as
steamer ovens and kettles. Do not locate the
Quickchiller in direct sunlight.
Allow sufficient front clearance for serviceability
and for easy maneuvering of food trolleys in and
out of the cabinet.

InSTallaTIon

Prior to moving the Quickchiller to the installation
site, check the dimensions of doors, passageways, and
ceiling heights in the areas through which the cabinet
must be moved. Also check the turning radius if the
cabinet must be moved around an existing structure.
The use of a fork lift or pallet lift truck is required for
moving and leveling most Quickchiller models.
noTe: In certain instances, it may be necessary
to remove doors and door hardware to
negotiate tight spaces.
®
danger

IMPROPER INSTALLATION,

ALTERATION, ADJUSTMENT,

SERVICE, OR MAINTENANCE COULD

RESULT IN SEVERE INJURY, DEATH,

OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION,

OPERATING AND MAINTENANCE

INSTRUCTIONS THOROUGHLY

BEFORE INSTALLING OR SERVICING

THIS EQUIPMENT.

InSTallaTIon
SITe InSTallaTIon