Installation
Mounting the Pump
•For ease of operation and service, mount the pump so the air inlet, fluid inlet, and fluid outlet ports are easily accessible.
•Mount the pump in a
•The pump must be mounted horizontally as shown in FIG. 1. Be sure that the pump is level in all direc- tions and that the cylinder housing (54) is positioned on the bottom. See FIG. 1.
•The pump can be floor mounted or mounted on a wall using mounting kit 246495.
•Be sure the mounting can support the weight of the pump, hoses, and accessories as well as the stress caused during operation. The pump has two mount- ing holes for 0.31 in. (8 mm) screws. See the Dimension drawing on page 26.
Hexagonal screw (2 required)
Fluid
Outlet
Floor Mount
Compressed air connection
Fluid Inlet
Cylinder
Housing (54)
TI2133A 2
Hexagonal screw
(2 required)
Wall mount using kit 246495:
1.Use the bracket (15C022) as a template to drill 2 0.38 (9.6 mm) diameter holes in the wall.
2.Loosely attach bracket (15C022) to the wall with anchors and screws (8 mm) long enough to prevent the bracket from vibrating during operation.
3.Remove bracket from the wall and fasten it to the pump using the 4 screws (116899) and 1 lock washer (100028) included in the kit.
4.The lock washer must be used in the unpainted hole to ensure proper grounding of the bracket.
5.Mount the bracket with the pump attached to the wall and tighten.
Wall Mount
FIG. 1. Mounting the Pump
Wall
Mount
Bracket
TI2469A
6 | 311688L |