Graco 311688L important safety instructions Ground all of this equipment, Grounding the Pump

Models: 311688L

1 28
Download 28 pages 32.17 Kb
Page 9
Image 9
Grounding

Grounding

Before operating the pump, ground the system as explained below. Read the warnings on page 4.

Ground all of this equipment:

Pump: use a ground wire and clamp. See FIG. 3. Loosen the grounding screw (X). Insert one end of a 12 ga (1.5 mm2) minimum ground wire (Y) under the clamp and tighten the screw securely. Connect the other end of the wire to a true earth ground. For a ground wire and clamp, order Part No. 222011.

Air and fluid hoses: Use only electrically conductive hoses.

Air compressor: Follow manufacturer’s recommen- dations.

Fluid supply drum: Follow your local code.

Installation

All fluid pails used when flushing: Follow your local code. Use only conductive metal pails placed on a grounded surface. Do not place the pail on a non- conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

X

Y

TI2126A

FIG. 3. Grounding the Pump

311688L

9

Page 9
Image 9
Graco 311688L important safety instructions Ground all of this equipment, Grounding the Pump