Electrical Requirements
Electrical Grounding Instructions
This appliance is equipped with a
wall receptacle in accordance with the National Electrical Code.
Room air conditioners are designed to operate according to requirements on the nameplate and as shown in Table 1. Fuse or circuit breaker ratings must be according to the fuse instruction label and as shown in Table 1. Do not plug models marked "Use on Single Outlet Circuit Only" into a circuit with another appliance or light fixture.
i _i WARNING
To avoid death, personal injury or property damage due to electrical shock, this unit
must be grounded. Do not under any
circumstances cut or remove the round
grounding prong from the plug. Do not use a
WARNING
To avoid death, personal inju ry or property damage due to electrical shock, do not use an extension cord. Do not pinch the power cord. Do not remove the warning tag from the power cord.
Unit Plug | Type | Receptacle | Circuit | Rating, | Voltage | Rating |
|
| Required | Breaker or | On Unit Nameplate | ||
|
|
| Time |
|
| |
|
|
| Delay | Fuse |
|
|
(_ |
|
| 115V | |||
NEMA No |
|
|
|
| ||
|
|
| 230/208V rated | |||
|
|
| at 12 amperes or less | |||
|
|
|
|
| ||
NEMA No | NEMA No |
|
|
|
| |
|
|
|
|
| 230/208V | rated over |
|
|
| 12 amperes | but not more | ||
NEMA No | NEMA No |
|
| than 16 ampf_res | ||
|
|
|
| |||
|
|
| 250V=30AMP | 230/208V rated | ||
|
|
| at 24 amperes or Eess | |||
|
|
|
|
| ||
NEMA No | NEMA No |
|
|
|
|
Table 1
Safety Features
This room air conditioner is equipped with an electronic control to improve comfort and ensure reliability.
Compressor Lockout
To extend the life of the compressor a three minute time delay will occur when:
Electrical power is first supplied to the unit
The thermostat is turned down immediately after the compressor stops running,
The Fan Control is quickly turned from FAN ONLY to COOLING mode or vice versa.
Low Voltage Protection
This unit is equipped with "brownout" protection. In case of an extreme brownout, the Amana control will interrupt power to the unit to prevent compressor failure. When the line voltage reaches at least 100 VAC, the control will re- energize your unit.
Note: A compressor lockout will occur after the unit is re- energized.
,Digital Temperature Setting
-Temperature can be set from 60°F to 90°F in I°F increments
,Digital Temperature Display
-Shows indoor room temperature in FAN ONLY mode
-Shows desired temperature setting in other modes ,Computer Memory that Remembers
-The unit remembers the last settings used when last turned on.
,TempAsure ® Thermostat
- Maintains set temperature within 1.5°F for maxi- mum comfort
,Smart Cool
,Energy Saver with TempAsure ® air sampling
,Delay Timer