GAS CONVERSIONS
2. Unplug or disconnect power.
3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4. Remove the cap from the gas pressure regulator using a
NOTE: Gas conversions (from Natural gas to LP gas or from LP gas to Natural gas) must be done by a qualified person.
LP Gas Conversion
To Convert Gas Pressure Regulator
1.Ensure that the manual shutoff valve is in the closed position.
A
B
C
A. Shutoff valve in “closed” position
B. Gas supply line
C. To range
5.Turn the cap over so that LP is visible.
A
A. Cap
6.Reinstall the cap.
To Convert Surface Burners
A
B
A. Burner cap
B. Burner
1.Remove burner grate, burner caps, and burners.
12