Amana AGG222VDW Natural Gas Conversion, To Convert Gas Pressure Regulator, A B C

Models: AGG222VDW

1 32
Download 32 pages 41.01 Kb
Page 14
Image 14
Natural Gas Conversion

Natural Gas Conversion

3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

NOTE: Gas conversions (from Natural gas to LP gas or from LP gas to Natural gas) must be done by a qualified person.

To Convert Gas Pressure Regulator

1.Ensure that the manual shutoff valve is in the closed position.

Manual background A

B

C

A. Shutoff valve in “closed” position

B. Gas supply line

C. To range

2.Unplug or disconnect power.

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4.Remove the cap from the gas pressure regulator using a flat- blade screwdriver.

5.Turn the cap over so that N or NAT is visible.

A

A. Cap

6.Reinstall the cap.

To Convert Surface Burners

1.Remove burner grates, burner caps, and burners.

Manual background A

B

A. Burner cap

B.Burner

2.Locate the Natural gas orifice spuds for the top burners in the bag containing literature included with the range. Two Natural gas spuds are stamped “149” and two “125.”

14

Page 14
Image 14
Amana AGG222VDW Natural Gas Conversion, To Convert Gas Pressure Regulator, To Convert Surface Burners, A B C