Amana AK2H36 Electrical Installation Requirements, Junction Box Location, Power Supply Connection

Models: AK2T30* AK2H30* AK2T36* AK2H36 AKT3000*

1 12
Download 12 pages 9.59 Kb
Page 6
Image 6
Electrical Installation Requirements

Electrical Installation Requirements

Installation of this product must conform with local codes or in the absences of local codes with the current National Electric Code ANSI NFPA 70 or Canadian Electrical Codes.

Cooktop requires a 3-wire 240 volt, 60 hertz, AC circuit protected by a separate 30 amp circuit breaker or time delay fuse.

Junction Box Location

Locate junction box within shaded area. (Figure 4)

If installed over Amana “AOES” or “AOCS” wall ovens, refer to cooktop over wall oven installation instructions for junction box location.

A

B

A—9 inches

B—8 inches

Figure 4

Power Supply Connection

Junction Box Location WARNING

To avoid risk of electrical shock, personal injury, or death, make sure cooktop has been properly grounded and always disconnect it from main power supply before any servicing.

To avoid risk of electrical shock or personal injury when connecting copper leads to aluminum house wiring, use only connectors designed for joining copper to aluminum. Follow connector manufacturer’s recommendations closely.

Models AK2H30 and AK2H36 Only

To avoid risk of electrical shock or personal injury, do not ground through neutral wire if installed in mobile home or if local codes do not permit grounding through neutral wire.

Cooktop has approximately 36 inches of flexible wire conduit attached to rear of cooktop. (Figure 5) Connect wire leads extending from conduit to house wires inside junction box (Junction box not included). Refer to local codes and attach according to options.

Option 1-United States or Canada (Cooktop Wire—House Wire) Bare—Ground (Green)

White—Neutral (White—AK2H30 and AK2H36 Only)

Red—Power Line (Red)

Black—Power Line (Black)

6

Page 6
Image 6
Amana AK2H36, AKT3000*, AK2T36* Electrical Installation Requirements, Junction Box Location, Power Supply Connection