Electrical Installation Requirements
Installation of this product must conform with local codes or in the absences of local codes with the current National Electric Code ANSI NFPA 70 or Canadian Electrical Codes.
Cooktop requires a
Junction Box Location
Locate junction box within shaded area. (Figure 4)
If installed over Amana “AOES” or “AOCS” wall ovens, refer to cooktop over wall oven installation instructions for junction box location.
A |
B |
Figure 4
Power Supply Connection
WARNING
To avoid risk of electrical shock, personal injury, or death, make sure cooktop has been properly grounded and always disconnect it from main power supply before any servicing.
To avoid risk of electrical shock or personal injury when connecting copper leads to aluminum house wiring, use only connectors designed for joining copper to aluminum. Follow connector manufacturer’s recommendations closely.
Models AK2H30 and AK2H36 Only
To avoid risk of electrical shock or personal injury, do not ground through neutral wire if installed in mobile home or if local codes do not permit grounding through neutral wire.
Cooktop has approximately 36 inches of flexible wire conduit attached to rear of cooktop. (Figure 5) Connect wire leads extending from conduit to house wires inside junction box (Junction box not included). Refer to local codes and attach according to options.
Option
6