Amana ARR3100*, ARR3400* Irregular Cabinet and Countertop Heights, Anti-tip Bracket Installation

Models: ARR3601* ARR3400* ARR3100*

1 20
Download 20 pages 53.36 Kb
Page 6
Image 6
Irregular Cabinet and Countertop Heights

Irregular Cabinet and Countertop Heights

Countertops such as ceramic tile tops cause cabinet and countertop to be higher than 36 inches. Follow instructions below when countertop is higher than 36 inches.

1.Raise leveling legs to maximum height.

2.Measure from floor to rangetop. If measurement is less than height of countertop, shim floor.

3.Shim floor using a piece of plywood same size as range opening. Secure plywood to floor. Plywood must be as secure as original flooring.

4.Install anti-tip bracket and slide range into place.

Anti-tip Bracket Installation

To reduce risk of range tipping, secure range with a properly installed anti-tip bracket.

1.Measure 31/2 inches from back wall on right and left side of cabinet cutout. Mark measurements on floor and draw a straight line connecting marks.

2.Position anti-tip bracket.

If range is installed beside cabinet(s), place anti-tip bracket with back edge on line drawn on floor and side of bracket against cabinet.

If range is not installed beside cabinet(s), position range where it will be installed. Draw a line along side of range on floor from front to back. Remove range. Place anti-tip bracket with back edge over line drawn 31/2 inches from back wall and side of bracket over line drawn along side of range on floor.

Anti-tip bracket can be installed on either right or left side.

3.Mark 2 hole locations in anti-tip bracket.

4.Drill 2 holes.

If drilling into wood, use a 3/32-inch drill bit.

If drilling into concrete, use a 3/16-inch masonry drill bit and insert plastic anchors.

5.Secure bracket to floor using screws supplied. Slide range into position.

6.Remove range storage drawer or panel and confirm anti-tip bracket is engaged with range leveling leg.

See “Removing Storage Drawer” or “Removing Panel” section.

3 1/2"

or

Anti-tip Bracket Installation

Line Voltage Requirements

Line voltage must not exceed rated voltage. See rating plate attached to range for kilowatt rating. Line voltage less than rated voltage will result in slow heating. Wiring system must conform to Underwriters Laboratories, Inc. standards and National Electrical Code. Installation must conform to all local, municipal and state building codes, and local utility regulations. Range must be connected only to a supply circuit as specified on rating plate wiring diagram of range.

This range requires 3 wires, 120/240 Volts, 60 Hertz A.C. House wiring and fusing must comply with local wiring codes. If no codes apply, wire according to National Electrical Codes.

Power Supply Location

Shaded area show range clearance for electrical connection.

A

 

 

 

A

 

 

E

B

C

D

A—3 inches

B—7 inches

C—6 inches

D—30 1/8 inches minimum

E—24 1/16

Power Supply Location

6