![Materials Needed (Not Supplied)](/images/new-backgrounds/69360/693605x1.webp)
Materials Needed (Not Supplied)
•Phillips screwdriver
•Pencil
•Ruler or tape measure and straight edge
•Protective gloves
•Carpenter square (optional)
•Tin snips (in some applications)
•Electric drill with 1/8 inch, 3/16 inch and 5/8 inch drill bits
•Hammer
•Stud finder (optional)
•Filler blocks, if needed for top cabinet spacing
•Saw (jig or keyhole)
•Charcoal filter kit (for inside recirculating installation)
•Filler panel kit (if space between cabinets is greater than 30 inches)
Materials Needed (Supplied)
Installation hardware is contained in packet shipped with microwave oven. Verify all parts listed below are included in packet.
4x2 inch Wood
ScrewsWashers
28 inch Pieces of Foam Tape
3/16 inch Toggle Bolts
Rectangular Washer
1/4 inch screws
HardwareQuantity
4 inch x 2 inch Wood Screws | 2 |
3/16 inch Toggle Bolts (and spring loaded nuts) | 4 |
1/4 inch Screws | 3 |
Washers | 3 |
Nylon Grommet (for metal cabinets) | 2 |
28 inch Pieces of Foam Tape | 2 |
Rectangular Washer | 1 |
Top Cabinet Template* | 1 |
Separately Packed Grease Filter* | 2 |
* Not Shown |
|
Hood Exhaust Duct
Outside ventilation requires hood exhaust duct. Use only metal duct. Read the following carefully.
Exhaust Connection: Hood exhaust has been designed to mate with standard 3 1/4 inch x 10 inch rectangular duct. If round duct is required,
Rear Exhaust: If rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs.
Maximum Duct Length: Total duct length of 3 1/4 inch x 10 inch rectangular or 6 inch diameter round duct should not exceed 140 equivalent feet for satisfactory air movement.
Elbows, Transitions, Wall and Roof Caps, Etc.
Elbows, transitions, wall and roof caps, etc., create additional resistance to airflow and are equivalent to a section of straight duct. When calculating total duct length, add equivalent lengths of all transitions and adaptors, plus length of all straight duct sections. Chart below shows approximate feet of equivalent length of some typical ducts.
Duct | Equivalent Length | |
5 FT. | ||
Adaptor | ||
| ||
Wall Cap | 40 FT | |
90° Elbow | 10 FT. | |
45° Elbow | 5 FT. | |
90° Elbow | 25 FT. | |
45° Elbow | 5 FT. | |
Roof Cap | 24 FT. |
Accessories Available for Purchase from
Dealer
•Charcoal filter kit: Charcoal filter kit is needed for recirculating exhaust installation.
•Filler panel kit: If space between cabinets is greater than 30 inches, filler panel kit may be used to fill in gap between microwave oven and cabinets.
* If