Amana PGB58B, PGC(24-60)B installation instructions Heating

Models: PGB58B PGC(24-60)B

1 33
Download 33 pages 11.48 Kb
Page 3
Image 3

MODEL

PGC42B0902A

PGC42B1152A

PGC48B0902A

PGC48B1152A

PGC60B0902A

PGC60B1352A

Cooling Capacity Btuh

42,000

42,000

48,000

48,000

60,000

60,000

SEER

12.20

12.20

12.00

12.00

12.00

12.00

Heating

 

 

 

 

 

 

Input Btuh

90,000

115,000

90,000

115,000

90,000

135,000

Output Btuh

72,000

89,000

72,000

89,000

72,000

108,000

AFUE

81.4

79.9

81.4

79.9

81.4

80.5

Temperature Rise °F

25-55

40-70

25-55

40-70

25-55

40-70

Number of Burners

4

5

4

5

5

6

Compressor

 

 

 

 

 

 

R.L. Amps

22

22

21.8

21.8

28.8

28.8

L.R. Amps

107

107

105

105

169

169

Condenser Coil

 

 

 

 

 

 

Face Area (sq. ft.)

17.2

17.2

17.2

17.2

17.2

17.2

Rows Deep

2

2

2

2

2

2

Fins/Inch

13

13

17

17

17

17

Condenser Fan

 

 

 

 

 

 

Diameter (in.)

24

24

24

24

24

24

CFM

3500

3500

3700

3700

4700

4700

Condenser Fan Motor

 

 

 

 

 

 

Horsepower

1/4

1/4

1/2

1/2

1/3

1/3

R.L. Amps

1.5

1.5

1.5

1.5

2.5

2.5

L.R. Amps

3.4

3.4

3.6

3.6

6.4

6.4

Blower Motor

 

 

 

 

 

 

Horsepower

3/4

3/4

3/4

3/4

1

1

R.L. Amps

5

5

5

5

7

7

L.R. Amps

 

Protected by redundant electronic control circuts

 

Blower Wheel Dia. x Width (in.)

10x10

10x10

10x10

10x10

11x8

11x8

Rated CFM, Cooling

1450

1450

1700

1700

1750

1750

Max. External

0.8" wc

0.8" wc

0.8" wc

0.8" wc

0.8" wc

0.8" wc

Combustion Blower

 

 

 

 

 

 

Diameter x Width (in.)

4 x 1.25

4 x 1.25

4 x 1.25

4 x 1.25

4 x 1.25

4 x 1.25

No.

1

1

1

1

1

1

Condenser Blower Motor

 

 

 

 

 

 

H.P.

0.03125

0.03125

0.03125

0.03125

0.03125

0.03125

F.L. Amps.

0.5

0.5

0.5

0.5

0.5

0.5

Press. Switch Setting (" W.C.)

-0.65

-0.65

-0.65

-0.65

-0.65

-0.65

Ignition - Lockout Timing (sec.)

4

4

4

4

4

4

Flame Sense Current (microamps)

 

 

 

 

 

 

Minimum

1

1

1

1

1

1

Maximum

6

6

6

6

6

6

Evaporator Coil

 

 

 

 

 

 

Face Area (Sq. Ft.)

5.7

5.7

5.7

5.7

5.7

5.7

Rows Deep

2

2

3

3

3

3

Fins/Inch

15

15

15

15

15

15

External Filter Size (Sq. Ft.)

5.3

5.3

5.3

5.3

5.3

5.3

Drain Line Size (in.)

3/4

3/4

3/4

3/4

3/4

3/4

Expansion Device (Cooling)

Capillary

Capillary

TEV

TEV

TEV

TEV

Refrigerant Charge

 

Refer to unit name plate for correct charge

 

Power Supply**

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

Min. Circuit Ampacity

34

34

39.5

39.5

49.7

49.7

Max. Overcurrent Device

50

50

50

50

70

70

Electrical Entrance Size

 

 

 

 

 

 

Power Supply

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

Low Voltage

7/8"

7/8"

7/8"

7/8"

7/8"

7/8"

Approx. Shipping Weight (lbs)

521

527

526

526

531

531

1)United States Installation

2)Specification subject to change without notice. See sales specification sheets for certain BTUH capacities.

3)This PGC series complies with requirements embodied in the American National Standard ANSI-Z21.47 Central Furnaces.

4)Filters are not supplied with units, but filters must be installed in the unit filter rack or in the return air system.

**While the above data is presented as a guide, it is important to electrically connect the unit and properly size overcurrent protection and wires in accordance with the National Electrical Code and all existing local codes.

Operating tolerance: Minus 5% on 208 VAC, Plus 10% on 208 VAC and 230 VAC, Minus 10% on 230 VAC

Table 1B

Gas Pack Specifications

3

Page 3
Image 3
Amana PGB58B, PGC(24-60)B installation instructions Heating

PGB58B, PGC(24-60)B specifications

Amana, a trusted name in heating and cooling, offers several high-efficiency gas furnace models, including the PGC(24-60)B and PGB58B. These furnaces combine innovation, reliability, and advanced technology to provide an optimal heating solution for any home.

One of the standout features of the Amana PGC(24-60)B is its modulating heating capability. This technology allows the furnace to operate at different heating levels based on the home’s demands. Instead of simply turning on and off, the PGC adjusts its output to maintain a consistent temperature, promoting energy efficiency and comfort. This not only reduces energy consumption but also minimizes temperature fluctuations, providing a more comfortable indoor environment.

The PGB58B model is designed with a focus on efficiency, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96%. This means that a higher percentage of the fuel used is converted into heat, making it one of the most efficient choices available. The combination of high-efficiency design and advanced components makes the PGB58B an excellent option for homeowners looking to reduce their energy bills while enjoying reliable heating performance.

Both models come equipped with a durable casing, ensuring longevity and performance. The rust-resistant and heavy-gauge steel construction protects against harsh weather conditions, making them suitable for various climates. Additionally, they feature a multi-speed blower motor, which optimizes airflow and enhances comfort by evenly distributing warm air throughout the home.

Advanced diagnostics and self-monitoring capabilities are integral to these models. The built-in diagnostic system enables quick identification of performance issues, allowing for timely maintenance and reducing repair costs. Furthermore, these furnaces are designed to be compatible with smart home technology, allowing homeowners to control their heating systems remotely and maximize energy efficiency.

In summary, the Amana PGC(24-60)B and PGB58B gas furnaces stand out for their innovative features and commitment to energy efficiency. With modulating heating, high AFUE ratings, durable construction, and smart technology compatibility, they offer reliable heating solutions that ensure comfort while keeping energy costs low. Homeowners can feel confident in their investment, knowing they have chosen a furnace that prioritizes both performance and sustainability.