Amana W10196158B wire connection Power supply cord, wire connection Direct wire, D C E F B Ag

Models: W10196158B

1 12
Download 12 pages 32.63 Kb
Page 8
Image 8
3-wire connection: Power supply cord

3-wire connection: Power supply cord

Use this method only if local codes permit connecting cabinet- ground conductor to neutral wire of power supply cord.

1.Use a ¼" nut driver and remove the hex washer head screws from the aluminum terminal blocks.

2.Connect the neutral (center) wire to the center terminal connector using one of the hex washer head screws. Securely tighten screw for proper electrical connection.

D

C

E

B

 

F

A

 

 

G

A. Line 1

E. Neutral (center) wire

B. Ground-link

F. Line 2

C. Hex washer head screw

G. UL listed strain relief

D. Silver-colored terminal

and 40- or 50-amp range

block screw

power supply cord

3.Connect the other 2 wires (lines 1 and 2) to the outer terminal screws on the terminal block.

4.Tighten strain relief screws.

5.Replace terminal block cover.

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the circuit breaker box or fused disconnect. Depending on your electrical supply, make the required 3-wire or 4-wire connection.

1.Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back 1" (2.5 cm) from the end of each wire.

1"

(2.5 cm)

3"

(7.6 cm)

2.Allow enough slack in the wire to easily attach the wiring terminal block.

3.Complete electrical connection according to your type electrical supply (4-wire or 3-wire electrical connection).

4-wire connection: Direct wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes

Recreational vehicles

In an area where local codes prohibit grounding through the neutral

1.Remove the ground-link screw from the range frame. Save the ground-link screw and cup washer. Bend the ground-link away from the range so that it does not contact the range.

Direct Wire Installation: Copper or Aluminum Wire4-wire connection: Direct wire C

B

A

A.Ground-link screw

B.Cup washer

C.Ground-link bent away from range

2.Connect the bare ground wire to the range using the ground- link screw and cup washer. The ground wire must be attached first and must not contact any other terminal.

D

C

E

F

B

AG

A. Bare wire from power

E. Line 2

supply cable

F. Neutral (white) wire

B. Line 1

G. UL listed strain relief and

C. Hex washer head screw

power supply cable

D.Silver-colored terminal block screw

3.Loosen (do not remove) the hex washer head screw and insert the neutral (white) wire under the screw clamp at the bottom of the center position terminal connector.

4.Insert the other 2 wires (lines 1 and 2) under the other 2 screw clamps.

B

AD

A.Insert wire under screw clamp.

B.Hex washer head screw

5.Securely tighten the hex washer head screws to

35 lbs-in. (4.0 N-m) minimum torque to make proper electrical connection.

6.Tighten the locking ring of the conduit connector.

7.Replace the terminal block cover.

8

Page 8
Image 8
Amana W10196158B wire connection Power supply cord, Direct Wire Installation Copper or Aluminum Wire, D C E F B Ag, C B A