Amcor AHD-65E Troubleshooting, Thank You, Energy Saving Tips, Problem, Cause, Solution, The Unit

Models: AHD-65E

1 6
Download 6 pages 3.9 Kb
Page 4
Image 4
Troubleshooting

Troubleshooting

Problem

Cause

Solution

Never try to repair or dismantle the air conditioner yourself. Tampering with the unit may result in the loss of warranty and can endanger the user and property.

The Unit

 

No power supply.

Make sure outlet works and the plug is

Does Nothing

 

 

pushed completely into the outlet.

 

 

 

 

 

 

Fuse is blown or circuit

Replace fuse or circuit.

 

 

was tripped.

 

 

 

 

 

 

 

Bucket is full.

Unit shuts off when bucket is full.

 

 

Drain the bucket.

 

 

 

 

 

 

 

Ambient temperature is

Unit will restart after shutting off

 

 

 

 

above 122° or below 32°F.

for 3 minutes.

 

 

 

 

Dehumidifier is

 

Normal operation in initial

Frost will usually disappear within 60

icing up.

 

stage of operation.

minutes unless temperature is below 60°F

 

 

 

 

Poor Airflow

 

Airflow is restricted

Make sure there are no curtains, blinds or

 

 

 

furniture blocking the front or back of unit.

 

 

 

 

 

 

Dirty Air Filter

Clean the filter.

 

 

 

 

NOTE: After prolonged usage, the condenser coils behind the filter may develop a residue buildup. Unless cleaned regularly with a soft brush, this residue will harden and may require special cleaning by a refrigeration/air conditioning serviceman.

Unit used for first time.

When first installed, allow at least 3 or 4

Unsatisfactory

days to remove the moisture from the room

Dehumidification

to maintain the desired dryness.

 

 

Area to be humidified

Check with dealer that model is

is too large.

suitable for room size and moisture level.

 

 

Controls not set correctly.

Adjust controls according to instructions.

 

 

Doors / windows not closed. Check that all openings are closed tightly.

Clothes dryer in operation

Install the dehumidifier away from the

in the same room.

moistureladen air generated by the dryer.

 

Dryer should be vented to the outside.

 

 

Room temperature too low.

The unit will not operate satisfactorily if the

 

room temperature is below 60°F.

 

 

If this product is defective or not working properly,

please DO NOT return to your retail store. Please contact Amcor for service or technical assistance.

www.amcorgroupusa.com

Thank You!

Thank you for purchasing an AMCOR Dehumidifier. AMCOR is a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Dehumidifier offers you.

AMCOR has specialized in complete indoor environment control, manufacturing world-class air conditioners, dehumidifiers and air purifiers with innovative technology.

In designing these advanced products, we have listened carefully to our customers and have passed their views on to our research and development laboratories.

We wish you many years of enjoyable use.

After reading this manual, please keep it in a safe place for future reference.

Energy Saving Tips

Do not locate the dehumidifier where furniture or other objects can obstruct the airflow.

Keep the filters clean.