EMPTYING THE INTERNAL WATER CONTAINER

GB

EMPTYING THE INTERNAL WATER CONTAINER

Under high humidity conditions it may be necessary to empty the internal water container. When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically.

To empty the water container do the following:

• Switch off the unit and remove the plug from the wall socket.

Do not move the unit. Doing this can result in water leakage, damaging your floor or carpet.

Place the water container on the floor underneath the permanent drainage point.

Remove the water stopper and rubber plug from the drain and let the water run out. The water container has to be emptied several times before all water will be drained (ca.

1.5 litres).

Replace the rubber plug and water stopper, put the plug into

the wall socket, and switch the unit on. The warning signal should be off.

NOTE! When the air conditioner is in use, under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose.

CONTINUOUS DRAINAGE

Switch off the unit and remove the plug from the mains.

Remove the water stopper and rubber plug.

Connect a drain tube (ø 20 mm inner dimension) onto the water outlet and extend with extra water tube if needed.

Place the other end in a normal drain. Make sure that the tube is free from twists and bends. The tube must decline over its entire length.

CLEANING

WARNING! First of all switch off the unit and remove the plug from the wall socket.

Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions.

Clean the screen filter regularly with a vacuum cleaner. See also “air filter” section. NOTE! Never use the air conditioner without the screen filter.