Amcor PCMA 9KE-410, PCMA 12KE-410, PCMA 15KE-410 user manual Repeated OFF and ON

Models: PCMA 15KE-410 PCMA 12KE-410 PCMA 9KE-410

1 15
Download 15 pages 58.51 Kb
Page 8
Image 8
Repeated OFF and ON

GB

Programming the timer for ON - when the unit is OFF.

• Perform the standard steps as described above.

The linear time scale will be on between the ON programmed times until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time, then the black segments in the linear time scale will disappear.

Programming the timer for OFF - when the unit is RUNNING.

• Perform the standard steps as described above.

The linear time scale will be on between the present time to the OFF programmed time. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the OFF timer time, then the black segments in the linear time scale will disappear.

Repeated OFF and ON

Programming the timer for repeat OFF and ON - when the unit is RUNNING.

Perform the standard steps as described above.

Repeat the above procedure while the digits are still flashing for setting the ON. The linear time scale will be ON between 00:00 to the time set with the timer to OFF and from the ON time until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes. The unit will operate daily according to the timer setting.

Repeated ON and OFF

Programming the timer for repeat ON and OFF - when the unit is NOT RUNNING.

Perform the standard steps as described above.

Repeat the above procedure while the digits are still flashing for setting the OFF. The linear time scale will be OFF between 00:00 to the time set with the timer to ON and from the OFF time until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes. The unit will operate daily according to the timer setting.

After a power failure, or after the unit has been unplugged, you will have to program the timer settings again.

Cancelling the timer function

In order to cancel the timer programming press the Manual background-button momentarily, then it will return to the time display. The daily mode will be cancelled as well. The black segments in the linear time scale will disappear.

LCD blue back light

In order to switch off the blue back light, press the Manual background- and Manual background-buttons at the same time. The blue back light will blink twice and goes off after three seconds.

By pushing any of the buttons the blue back light will come on again.

8

Page 8
Image 8
Amcor PCMA 9KE-410, PCMA 12KE-410, PCMA 15KE-410 user manual Repeated OFF and ON