Amcor PCMA 9KE-410, PCMA 12KE-410, PCMA 15KE-410 user manual Technical Data, Model, Pcma

Models: PCMA 15KE-410 PCMA 12KE-410 PCMA 9KE-410

1 15
Download 15 pages 58.51 Kb
Page 14
Image 14
TECHNICAL DATA

GB

TECHNICAL DATA

Model

 

PCMA

PCMA

PCMA

 

 

9KE-410

12KE-410

15KE-410

 

 

 

 

 

Cooling capacity

BTU/h

7500

9900

11300

 

 

 

 

measured conform EN 14511

kW

2.2

2.9

3.3

 

 

 

 

 

 

Power consumption

kW

0.77

0.99

1.36

 

 

 

 

 

Current

A

3.4

4.3

5.9

 

 

 

 

 

Mains

V / Hz / Ph

 

220 – 240 / 50 / 1

 

 

 

 

 

 

Fan speeds

 

 

3

 

 

 

 

 

 

Thermostatic range

°C

 

18 – 32

 

 

 

 

 

 

Protection class

 

 

IP 21

 

 

 

 

 

 

Refrigerant

type

 

R410A

 

 

 

 

 

 

Refrigerant load

g

420

500

630

 

 

 

 

 

Dimensions (w x h x d)

mm

 

500 x 840 x 415

 

 

 

 

 

 

Net weight

kg

33.1

34.3

39.3

 

 

 

 

 

PCMA 9KE-410 series can be connected only to a supply with system impedance no more than 0.383 Ohm. PCMA12KE-410 series can be connected only to a supply with system impedance no more than 0.247 Ohm. PCMA15KE-410 series can be connected only to a supply with system impedance no more than 0.110 Ohm. If necessary, please consult your supply authority for system impedance information.

Subject to modifications without prior notice.

For greater precision, please refer to the rating label placed on the product.

Reminder:

Waste electrical products must not be disposed of with household waste.

This product should be taken to your local recycling centre for safe treatment.