Amcor PCMB-12000EH owner manual Maintenance, Cleaning the Unit, Cleaning the “Upper” Filter

Models: PCMB-12000EH PCMB-12000E

1 20
Download 20 pages 59.45 Kb
Page 16
Image 16
Maintenance

Maintenance

Always unplug the unit from the wall before performing any maintenance.

Make sure the unit is drained before moving.

Cleaning the Unit:

Only use a soft damp cloth.

Never use chemicals, oil-based products, detergents, or other cleaning solutions. These could damage the cabinet.

Cleaning the “Upper” Filter:

Slide out the filter holder from the unit.

Separate the filter fixer from the filter holder (see fig. 1).

Remove the active carbon filter (black) and slide out the 3M™ High Air Flow filter (white).

To clean filters, vacuum with standard vacuum cleaner.

Insert the active carbon filter into the filter holder (see fig. 2).

Insert the 3M™ High Air Flow filter into the filter holder (see fig. 3).

Fix the filters by reassembling the fixer into the filter holder (see fig. 4).

Cleaning the “Lower” Filter:

• Vacuum with standard vacuum cleaner.

NOTE:

Before storage be sure filters are clean and dry.

Should you need to replace filters, contact Amcor for replacement.

The screen filter must always be used.

The 3M™ High Air Flow filter should be cleaned periodically. Both filters can be vacuumed.

IMPORTANT: NEVER operate the unit without a filter.

End of Season Storage:

Unplug the unit.

Drain the condensed water COMPLETELY.

Clean the upper and lower filter.

14

Page 16
Image 16
Amcor PCMB-12000EH owner manual Maintenance, Cleaning the Unit, Cleaning the “Upper” Filter, Cleaning the “Lower” Filter