English

Step 5:

Next, select the hard drives which you wish to be included in the disk array. The Free Disks section displays the information about the currently installed SATA hard drives. Press the TAB key to move to the Free Disks section. Select the target hard drives using the UP or DOWN ARROW key and use the RIGHT ARROW key to add the hard drives to the Array Disks section (Figure 6).

MediaShield Utility Aug 21 2006

- Define a New Array -

RAID Mode: Striping

 

 

Striping Block: Optimal

 

Free Disks

 

 

Array Disks

 

Port

Disk Model

Capacity

 

Port

Disk Model

Capacity

 

 

 

 

1

ST3120026AS

111.79GB

 

 

[

] Add

2

ST3120026AS

111.79GB

 

 

[

] Del

 

 

 

 

[ESC] Quit

[F6] Back [F7] Finish

[TAB] Navigate

[ ] Select

[ENTER] Popup

Figure 6

Step 6:

Press F7 after selecting the target hard disks. A message which says "Clear disk data?" will appear (Figure 7). If you are sure to clear the data in the selected hard drives, press Y. (If the hard drives contain previously created RAID array, you need to press Y to clear the data from the hard drives.)

MediaShield Utility Aug 21 2006

- Define a New Array -

RAID Mode: Striping

 

 

Striping Block: Optimal

 

Free Disks

Clear disk dataArray? Disks

 

Port

Disk Model

Capacity

 

Port

Disk Model

Capacity

 

 

Clear disk

1.0.M

ST3120026AS

111.79GB

 

 

[Y] YES [N] NO

ST3120026AS

111.79GB

 

 

[

] Add

1.1.M

 

 

[Y] YES

[N] NO

 

 

 

 

[

] Del

 

 

 

 

[ESC] Quit

[F6] Back [F7] Finish

[TAB] Navigate

[ ] Select

[ENTER] Popup

Figure 7

GA-M61P-S3 Motherboard

- 66 -

Page 66
Image 66
AMD 701P47156 user manual Yes