Americair 4000HV, 2500HV Independent Operation, Dealer Installation Instructions, Preparation

Models: 2500HV 6000V 8500 & 10000 6500 4000HV

1 16
Download 16 pages 25.47 Kb
Page 11
Image 11
Independent Operation:

Dealer Installation Instructions

Independent Operation:

The HEPA systems can be used independently of any other equipment! The intake and outflow of the filtration system can be ducted into the same room to create a cleaner environment almost anywhere. The intake or out- flow can also be ducted elsewhere. The intake and outflow should be installed on opposite sides of the room; however, this varies according to your specific needs.

Preparation:

 

Example of Single Room Stand Alone System Installation

Here are some things to consider as you

 

For single rooms where increased filtration is desired such as a

decide where to install the HEPA system

 

dedicated ‘smoking room’.

 

independently of other systems.

 

HEPA System

 

 

 

 

 

 

 

 

 

Air should be drawn from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

location B if space is avail-

 

 

 

 

 

 

 

 

 

 

 

• Make sure there is room to open the

 

 

 

 

 

 

 

 

 

 

 

able, otherwise, use loca-

HEPA filter access panel for filter

 

A

tion A.

changes/inspections.

 

 

 

 

 

 

 

 

 

 

 

 

• Keep the HEPA system away from

 

 

 

 

 

 

possible water damage

 

 

 

 

 

 

• Vibration pads will reduce vibration for

 

 

 

 

 

 

installations where the unit is placed

B

 

 

 

 

 

on the floor.

 

 

 

 

 

• Install HEPA System on floor or

 

 

 

 

 

 

 

 

Figure 17.

 

 

suspended platform. If the unit is

 

 

 

 

suspended, screws must not pene-

 

 

 

 

 

 

 

 

 

 

• Externally insulated flex duct can also be used for

 

trate through the cabinet. Make sure that you

 

 

 

have the proper chains/straps/joists and equip-

 

 

noise reduction purposes.

 

 

ment to keep unit secure.

 

 

• For best indoor air quality, do not use ductboard or

 

 

 

 

 

fiberglass inside of ducts.

 

 

Intake (Marked as ‘Air In’ on unit):

 

 

Electricity:

 

 

• Intake ducts should be installed near the floor for

 

• The unit must be plugged into a grounded 120V,

 

optimum airflow (see figure 11). If space does not

 

60Hz. outlet.

 

 

allow, then the inlet can be installed in the ceiling.

 

Required Materials for Installation of Unit:

 

• Intake duct should be installed at least 6 ft. away

 

 

from the outflow duct.

 

 

Items for 2500HV & 4000HV

 

 

• Intake duct should be installed at opposite end of

 

Flex or rigid duct

6” round

 

the room from the outflow duct(s) if in the same room.

 

(length as required)

 

 

• Diffusers are recommended to help distribute air-

 

Takeoffs

Two 6”

 

flow evenly.

 

 

Diffusers

Two 6”

 

 

 

 

 

Items for 6000V

 

 

Outflow (Marked as ‘Clean Air Out’ on unit):

 

 

Flex or rigid duct

10” round & 8” round

 

• Outflow(s) should be installed in the ceiling away

 

(length as required)

 

 

from any other air inlet(s)

 

 

Takeoffs

One 10” & One 8”

 

• Room diffusers are recommended to help dis-

 

 

Diffusers

One 10” & One 8”

 

tribute airflow evenly in the occupied space.

 

 

Items for 6500, 8500 & 10000

 

 

 

 

 

 

Flex or rigid duct

10” x 12”

 

Ducting:

 

 

(length as required)

 

 

• If HEPA system is installed where inlet and outflow

 

Takeoffs

Two 10”x12”

 

collars face down, metal elbows must be connected

 

All Models

 

 

to both inlet and outflow collars.

 

 

Aluminum tape or mastic as required

 

• Each connection must be sealed with aluminum

 

Misc. hanging materials - field provided

 

tape or mastic, including all vent connections.

 

 

NOTE: Be sure to review ‘Rules for Safe Installation

 

• Installed duct runs should be as straight as possi-

 

 

ble (if the duct runs are too long, reduced CFM

 

 

and Operation’ on page 1 of this document before

 

may result).

 

 

start-up of this unit.

 

 

• If duct is exposed to unconditioned air, insulated

 

 

 

 

 

flex duct is highly recommended.

 

 

 

 

 

 

11

Page 11
Image 11
Americair 4000HV, 8500 & 10000 Independent Operation, Dealer Installation Instructions, Preparation, start-upof this unit