# erialS # odelM
INSTALLATION INSTRUCTIONS
WARNING: DISCONNECT POWER BEFORE INSTALLING
Note: Automatic dryers DESUNAare not recommendedLA ELECTRICIDADforANTEShair dryingDE HACERuse. REPARACIONES
1. Removal of cover:
A) Remove special allen screw using wrench supplied.
B) To remove cover, place a hand on each side of cover and pull bottom
toward you about 1/4 inch, then push cover up toward top of dryer, releasing cover from mounting plate latch. Lift cover off mounting plate by pulling forward at the bottom and upward at the same time. DO NOT FORCE COVER OFF.
2. REMOVE (2) bolts, washers & nuts from lower mounting holes of automatic dry- ers.
3. Dryers should be placed at least 2 feet (61cm) apart and at least 12” (30cm) from washbasin. Do not install dryer over washbasin. Automatic dryers should be at least 18” (46cm) above any projection which may interfere with the operation of the automatic sensor.
Hold the backplate to the wall at the suggested mounting height. Measure from bottom edge of backplate to the floor (Ref. Dimension “A” Fig. 1)
DR- Hand Dryer |
| WOMEN | (depends on age) | DISABLED | |
40” (102cm) | 38”(97cm) | 32” | (81cm) | ||
42” (107cm) | 40”(102cm) | 34” | (86cm) | ||
| 72” (183cm) | 68”(173cm) | 52”(132cm) |
4. Mark the locations of the four mounting holes and the conduit entrance location on the wall. (The conduit entrance is the proper hole diameter for 1/2 inch (13mm) conduit.)
5. Fasten the backplate to the wall where previously marked.
RECOMMENDATION:
Wood wall - No. 16 (M8) wood screws, 2 3/4” (70mm) long Cement or brick - 1/4” (M6) stud expansion bolts, 3” (76mm) long Hollow wall - 1/4” (M6) toggle bolts, length depends on wall thickness
6. Run service wire to the dryer location and connect to the terminal block. IMPORTANT: All units must be supplied with 3 wire service. Use No. 12 wire or larger, as required by local electrical code. The ground wire must be connected to the dryer backplate. Unit must be installed by a qualified licensed electrician.
Connect to a dedicated circuit NOT to exceed 20 amps.
Dryers located in shower rooms or other wet locations should be equipped with ground fault interrupter(s).
7. Carefully replace the cover using
AMERICAN DRYER, INC.
12932 FARMINGTON ROAD, LIVONIA, MI 48150, U.S.A.
Telephone (734)
www.americandryer.com • Email: sales@americandryer.com
CHILDRENMEN
______
______
OWNER’S MANUAL
“DR” HAND and Hair DRYERS
For Installation or Service
Assistance Please Call
(734) 421-2400 or
Email: sales@americandryer.com
Important: Have Model & Serial No. Ready
Rev. September 2006