19
IMPORTANT: Figures shown are for non-reversing models ONL Y.
IMPORTANT: The wire size must be properly sized to handle the related current.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.

Gas

Electric

AD-20

ELECTRIC AL S ERVI C E S P EC I F IC ATION S ( P ER DRYER)

NOTES: A.
B.
C.
When fuses are used they must be dual element, time delay, current limiting, class
RK1 or RK 5 ON LY. Calculate/determine correct fuse value, by applying either
local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY . For
others, calculate/verify correct breaker size according to appliance amp draw
rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE PHASE WIRE
SERVICE
APPROX.
AMP DRAW CIRCUIT
BREAKER
60 Hz 50 Hz
120 2 10.9 --- 15
240 1ø 3 6 15
240 3 5.8 --- 15
240 3 --- 28.5 35
240 3 28.3 --- 35
416 4 -- - 18 25