Dryer Enclosure Requirements _______

Bulkheads and partitions should be made of noncombustible material.

Note

!Allowances must be made for opening the control door.

AThe optimum opening of load door is 30-inches (76.2 cm) for ADH-75; and 38-1/4” (76.2 cm) for ADH-120 and ADH-170.

BThe maximum thickness of the bulkhead is 4-inches (10.16 cm). For electric dryers the maximum thickness of the bulkhead is 1-inch (2.54 cm) within 3-inches (7.62 cm) from the top of the control door.

CFor electric dryers a minimum overhead clearance of 12-inches (30.48 cm) is required, providing no sprinkler is located above the dryer. For steam dryers or if a sprinkler is located above the dryer, 18-inches (45.72 cm) is required.

DDryer should be positioned 12-inches (30.48 cm) for ADH-75; 24-inches (60.96 cm) for ADH-120 and ADH-170, away from the nearest obstruction and 24-inches (60.96 cm) for ADH-75; 36-inches (91.44 cm) for ADH-120 and ADH-170 is recommended for ease of installation, maintenance, and service.

EFlush to the opening of the control door.

FFlooring should be level or below dryer cabinet for ease of removing panels during maintenance.

GDryers may be positioned sidewall to sidewall, however a 1/16” (1.5875 mm) minimum allowance must be made for the opening and closing of the control door, along with the removal of panels during maintenance.

Fresh Air Supply Requirements _______

When the dryer is operating, it draws in room air, heats it, passes this air through the tumbler, and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch “fluttering” problems may result, as well as premature motor failure from overheating. The dryer must be installed with provisions for adequate combustion and make-up air supply.

Air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) ADH-75; 3 square feet (0.28 square meters) ADH-120; 4 square feet (0.37 square meters) ADH-170; is required for each dryer.

ADH-75

A = 2 ft (0.61 m)

B = 18” (45.72 cm)

ADH-120

A = 2 ft (0.61 m)

B = 3 ft (0.91 m)

ADH-170

A = 3 ft (0.91 m)

B = 3 ft (0.91 m)

To compensate for the use of registers or louvers used over the openings, this area must be increased by approximately thirty-three percent (33%). Make-up air openings should not be located in an area directly near where exhaust vents exit the building.

It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to all the dryers.

ADH-120 EXAMPLE: For a bank of 4 dryers, 2 unrestricted openings measuring 2 feet by 3 feet (0.61 meters by 0.91 meters) are acceptable.

Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas.

Important

!Make-up air must be provided from a source free of dry cleaning solvent fumes. Make-up air that is

contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components.

Note

!Component failure due to dry cleaning solvent fumes will void the warranty.

113247 - 3

www.amdry.com

17

Page 17
Image 17
American Dryer Corp ADH-75, ADH-170, ADH-120 installation manual Dryer Enclosure Requirements, Fresh Air Supply Requirements

ADH-120, ADH-75, ADH-170 specifications

American Dryer Corp is renowned for its high-quality commercial dryer machines, catering to the needs of various industries, particularly in laundromats, hospitality, and healthcare. Among their extensive lineup, the ADH-170, ADH-75, and ADH-120 stand out for their efficiency, durability, and innovative technology designed to enhance user experience and operational efficiency.

The ADH-170 is a heavy-duty dryer known for its impressive capacity and rapid drying times. With a substantial drum size, it can accommodate large loads, making it ideal for high-traffic commercial environments. This model features advanced moisture sensing technology that automatically adjusts drying times based on the moisture content of the load, ensuring optimal performance while conserving energy. The durable construction and rust-resistant materials also mean that the ADH-170 is built to withstand the rigors of daily use.

The ADH-75 is designed for establishments that require a balance of capacity and efficiency. It offers a slightly smaller drum size compared to the ADH-170 but maintains robust performance characteristics. This model is equipped with an intuitive control panel that allows operators to select various drying cycles and settings, optimizing the dryer’s performance for different fabric types. The ADH-75 also incorporates energy-saving features, such as a cool-down cycle that helps prevent fabric from overheating, thus prolonging garment life.

The ADH-120 is a versatile dryer that strikes an excellent balance between capacity and flexibility. This model comes with an innovative air-flow design, promoting quicker drying times and reducing energy consumption. Its ergonomic design ensures ease of use, while safety features protect operators and users alike. Furthermore, the ADH-120 is outfitted with user-friendly controls that provide programmable settings, making it suitable for various commercial applications.

Overall, the American Dryer Corp ADH series exemplifies a commitment to quality and performance in commercial laundry solutions. From the high-capacity ADH-170 to the efficient ADH-75 and the adaptable ADH-120, each model integrates advanced technology and robust design, making them reliable choices for businesses looking to optimize their laundry operations. With their user-friendly features and energy-efficient solutions, American Dryer Corp continues to set the standard in the commercial dryer market, ensuring customer satisfaction and operational excellence.