Preparation for Operation/Start-Up ___

The following items should be checked before attempting to operate the dryer:

Read all “CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.

Check incoming supply voltage to be sure that it is the same as indicated on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service exactly.

ELECTRIC MODELS – The sail switch damper assembly was installed and adjusted at the factory prior to shipping. However, each sail switch adjustment must be checked to ensure that this important safety control is functioning. (Refer to Sail Switch Adjustment in the Preoperational Test section).

Be sure all back panels (guards) and electric box covers are in place.

Be sure the service doors are closed and securely in place.

Be sure the lint door/drawer is securely in place.

Rotate the tumbler (drum) by hand to be sure it moves freely.

Check bolts, nuts, screws, terminals, and fittings for tightness and security.

STEAM MODELS – check to ensure that a clean, dry, regulated air supply (80 psi [5.51 bar]) is on the dryer (with air-operated damper system only).

STEAM MODELS – Check to ensure all steam shutoff valves are open.

STEAM MODELS – Check steam damper operation.

Check tumbler bearing setscrews to ensure they are all tight.

Check that the vent is connected to the dryer and is exhausted to the outdoors.

Preoperational Test ___________________

All dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

Turn on electric power to the dryer.

Refer to the Operating Instructions for starting your particular model dryer.

Steam Dryers

Check to ensure that steam damper is functioning properly. The steam damper should not “slam” (open or closed) when it reaches the end of (piston) travel. Additionally, the steam damper should not bind and/or stop during travel. If either of these conditions occur, the flow control must be adjusted. Refer to the Steam Damper Air Piston (Flow Control) Operation Adjustment instructions in the Steam Information section.

Electrical Dryers

Check to ensure that electric oven/contactor assembly is activating.

Safety Related Circuits

Make a complete operational check of all safety related circuits:

Door Switch(es)

Hi-Limit Thermostats

Sail Switch (for Electric Models Only)

Sail Switch Adjustment – To check for proper sail switch operation (for electric models only), open the main door and while holding main door switch plunger in, start dryer. Dryer should start but heat circuit should not be activated (on). If the heat system is activated, the sail switch is improperly adjusted and must be adjusted by bending the actuator arm of the sail switch toward the burner box. If the actuator arm is bent too far toward the burner box of the dryer, the dryer may not have heat when needed. After any adjustment to the sail switch, the above procedure must be repeated to verify proper operation of the sail switch.

The dryer should be operated through 1 complete cycle to ensure that no further adjustments are necessary and that all components are functioning properly.

Make a complete operational check of all operating controls.

For microprocessor model check controller (computer) programs/selections: each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly used parameter (program) selections. If computer program changes are required, refer to the computer programming manual which was shipped with the dryer.

Tumbler Coating

The tumbler is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating.

3-Phase (3ø) Electric Service

Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check to see if the blower/fan is rotating in the proper direction. Looking from the front, the blower/fan should spin in the CW direction. If it is, the phasing is correct. If the phasing is incorrect, reverse 2 of the 3 leads at connections L1, L2, L3 of the power supply to the dryer.

Important

!If the blower/fan is rotating in the wrong direction, it will drastically reduce drying efficiency and it can

also cause premature component failure.

Spin and Dwell (Stop) Times Adjustment

Reversing tumbler dryers should never be operated with less than a 66% load (dry weight), since the load’s weight affects tumbler coast time during a direction reversal command. It is important that the tumbler come to a complete stop prior to starting in opposite direction.

113247 - 3

www.amdry.com

29

Page 29
Image 29
American Dryer Corp ADH-75, ADH-170, ADH-120 installation manual Preparation for Operation/Start-Up, Preoperational Test

ADH-120, ADH-75, ADH-170 specifications

American Dryer Corp is renowned for its high-quality commercial dryer machines, catering to the needs of various industries, particularly in laundromats, hospitality, and healthcare. Among their extensive lineup, the ADH-170, ADH-75, and ADH-120 stand out for their efficiency, durability, and innovative technology designed to enhance user experience and operational efficiency.

The ADH-170 is a heavy-duty dryer known for its impressive capacity and rapid drying times. With a substantial drum size, it can accommodate large loads, making it ideal for high-traffic commercial environments. This model features advanced moisture sensing technology that automatically adjusts drying times based on the moisture content of the load, ensuring optimal performance while conserving energy. The durable construction and rust-resistant materials also mean that the ADH-170 is built to withstand the rigors of daily use.

The ADH-75 is designed for establishments that require a balance of capacity and efficiency. It offers a slightly smaller drum size compared to the ADH-170 but maintains robust performance characteristics. This model is equipped with an intuitive control panel that allows operators to select various drying cycles and settings, optimizing the dryer’s performance for different fabric types. The ADH-75 also incorporates energy-saving features, such as a cool-down cycle that helps prevent fabric from overheating, thus prolonging garment life.

The ADH-120 is a versatile dryer that strikes an excellent balance between capacity and flexibility. This model comes with an innovative air-flow design, promoting quicker drying times and reducing energy consumption. Its ergonomic design ensures ease of use, while safety features protect operators and users alike. Furthermore, the ADH-120 is outfitted with user-friendly controls that provide programmable settings, making it suitable for various commercial applications.

Overall, the American Dryer Corp ADH series exemplifies a commitment to quality and performance in commercial laundry solutions. From the high-capacity ADH-170 to the efficient ADH-75 and the adaptable ADH-120, each model integrates advanced technology and robust design, making them reliable choices for businesses looking to optimize their laundry operations. With their user-friendly features and energy-efficient solutions, American Dryer Corp continues to set the standard in the commercial dryer market, ensuring customer satisfaction and operational excellence.