American Dryer Corp HBG76 manual Electrical Information, Electrical Requirements

Models: HBG76

1 22
Download 22 pages 53.55 Kb
Page 11
Image 11

A = 8-inch (20.32 cm)

B =12 feet (3.656 meters)

NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening.

NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction.

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

640 cfm (18.12 cmm) Exhaust Connections at Common Duct

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SQ IN

164

120

80

54

SECTIONAL AREA

SQ CM

1058

774.2

516.1

348.4

MINIMUM ROUND

IN

14

12

10

8

DUCT DIAMETER

CM

35.56

30.48

25.4

20.32

Electrical Information ________________

Electrical Requirements

All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local, state, and national regulations or codes of the country of origin. In the absence of such codes, all electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

Important: Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual can result in personal injury or component failure.

Note: Component failure due to improper installation will void the warranty.

Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. Do not use aluminum wire, which could cause a fire hazard. The copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections.

Note: The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to each dryer, do not daisy chain.

Component failure due to improper voltage application will void the warranty.

The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

Important: A separate protected circuit must be provided to each dryer.

The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

The wire size must be properly sized to handle the related current.

Warning

!208 VAC and 240 VAC are not the same. Any damage done to dryer components due to

improper voltage connections will automatically void the warranty.

Warning (Gas Models Only)

!Dryers built for use with a voltage between 200 and 240 must verify the input voltage during

installation. If the nominal

 

 

 

voltage is outside of the

TERM

LINE VOLTAGE

medium tolerances shown

 

 

 

50 Hz

60 Hz

on the diagram below,

 

 

 

 

260

283

adjust the autotransformer,

HIGH

226

249

located near the burner

 

 

239

260

assembly. To adjust the

MED

208

230

autotransformer wiring,

 

place the red wire on the

LOW

217

236

appropriate tap (HIGH,

189

208

 

MED, LOW) of the

autotransformer. For additional wiring details, refer to the electrical diagram located on the inside of the control panel.

Electrical Service Specifications

Gas and Steam Models Only

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX. AMP DRAW

CIRCUIT

VOLTAGE

SERVICE

 

 

BREAKER

 

60 Hz

50 Hz

 

 

Gas

 

 

120

2

25.5

35

208

2

19.8

25

220

2

14.2

12.3

20

230

2

12.2

20

240

2

13.4

20

 

 

Steam

 

 

120

2

22.2

30

200

2

12.0

20

208

2

12.0

20

220

2

12.0

9.6

20

230

2

10.0

20

240

2

11.3

20

7/10/08

113615 -1

www.amdry.com

11

Page 11
Image 11
American Dryer Corp HBG76 manual Electrical Information, Electrical Requirements

HBG76 specifications

American Dryer Corp (ADC) has established itself as a leading provider of high-quality laundry equipment, and their HBG76 model is a prime example of innovative design and advanced technology in commercial dryers. The HBG76 is engineered for efficiency, versatility, and durability, making it an ideal choice for laundromats, hotels, and other commercial laundry operations.

One of the main features of the HBG76 is its robust construction. Built with high-grade materials, the dryer offers exceptional longevity and reliable performance, capable of withstanding the rigors of frequent use. Its exterior is designed not only for durability but also for ease of maintenance, with convenient access points for servicing and cleaning.

The HBG76 incorporates state-of-the-art drying technologies aimed at maximizing efficiency and reducing energy consumption. One notable aspect is its powerful yet efficient heating system, which rapidly raises and maintains optimal temperature levels. This feature allows for shorter drying cycles, ultimately increasing throughput and profitability for operators.

Additionally, the HBG76 features advanced airflow technology, ensuring that every load receives uniform drying. With strategically placed ventilations, the dryer enhances air circulation within the drum, preventing clumping and allowing for even heat distribution. This results in thoroughly dried laundry without the risk of over-drying or damage to delicate fabrics.

Another significant characteristic of the HBG76 is its user-friendly interface. The dryer is equipped with a programmable control panel that allows operators to set specific drying times and temperatures according to the needs of different fabric types. This flexibility ensures that various laundry loads, ranging from heavy towels to delicate garments, can be processed with precision.

A crucial aspect of the HBG76 is its commitment to energy efficiency. With energy-saving features and options for environmentally friendly operation, the dryer is designed to reduce utility costs while still delivering high-performance results. This not only benefits the environment but also enhances the bottom line for commercial laundry providers.

In conclusion, the American Dryer Corp HBG76 stands out in the competitive landscape of commercial dryers. Its combination of durable construction, innovative drying technologies, user-friendly controls, and energy-efficient features make it a smart choice for any laundry operation looking to improve efficiency and effectiveness. With the HBG76, operators can expect reliable performance and excellent results, all while being mindful of operating costs and environmental impact.