Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-2

 

 

INSTALLATION

 

A-2

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 355

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AC VOLTAGE & DC OUTPUT

 

 

Product

Ordering

Input AC

Rated DC Output

Output

Weight

Dimensions

 

Name

Information

Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

 

 

 

 

 

(continuous)

 

 

 

 

 

 

 

 

 

 

 

Power

 

200-208

 

 

 

 

 

Wave

K2152-1

220-240

350A / 34V / 60%

 

 

14.8” x 13.3” x

 

355

 

380-415

1 & 3 Phase

AMPS

 

 

 

(81.5 lbs.)

27.8”*

 

 

 

440-480

 

 

 

 

 

 

(37.0 kg.)

(373 x 338 x

 

 

 

575

 

5-425

 

 

 

 

 

706*)mm

 

 

 

 

 

 

 

 

 

60/50 HZ

300A / 32V / 100%

 

 

*Includes

 

 

 

 

 

Handles

 

 

 

 

1 & 3 Phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Overall Length Including Handle, 21.6” (549mm) without handle.

POWER WAVE 355 INPUT CURRENT

Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Phases

300Amps @

350Amps @

Line Cord

Fuse size

Notes

 

 

32Volts(100%)

34Volts(60%)

AWG

 

 

 

 

200

1

Not

Not

 

---

Note 1

 

 

 

 

Recommended

Recommended

 

 

 

 

 

208

1

76

94

2

125A

Note 2

230

1

69

85

4

125A

Note 2

380

1

Not

Not

 

---

Note 1

 

 

Recommended

Recommended

 

 

 

 

 

400

1

Not

Not

---

---

Note 1

 

 

 

Recommended

Recommended

 

 

 

 

 

415

1

41

64

6

80A

Note 2

460

1

36

42

8

70A

 

 

 

575

1

31

37

8

50A

 

 

 

 

 

 

 

 

 

 

200

3

41

50

6

80A

Note 2

208

3

39

50

6

80A

Note 2

230

3

36

42

8

70A

 

 

 

380

3

23

28

8

50A

 

 

 

400

3

22

27

8

50A

 

 

 

415

3

22

26

8

50A

 

 

 

460

3

19

23

8

50A

 

 

 

575

3

16

18

8

35A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. Not rated is indicated by 4-x’s in the box on the rating plate.

Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Select The output cable size based upon the following chart.*

 

Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

 

 

 

 

 

 

DUTY CYCLE

CURRENT

LENGTH UP 200FT.(61m)

 

200-250 FT. (61-76m)

100%

300

1/0

 

1/0

60%

350

1/0

 

2/0

 

 

 

 

 

*Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.

POWER WAVE 355/405

Page 10
Image 10
Lincoln Electric SVM159-A service manual Installation, Technical Specifications Power Wave