| INSTALLATION |
| ||||
|
|
|
|
|
|
|
|
TECHNICAL SPECIFICATIONS - POWER WAVE 355 |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| INPUT AC VOLTAGE & DC OUTPUT |
|
| ||
Product | Ordering | Input AC | Rated DC Output | Output | Weight | Dimensions |
|
Name | Information | Voltage | Amps/Volts/Duty Cycle | Range | with Cord | HxWxD |
|
|
|
|
| (continuous) |
|
|
|
|
|
|
|
|
|
|
|
Power |
|
|
|
|
|
| |
Wave | 350A / 34V / 60% |
|
| 14.8” x 13.3” x |
| ||
355 |
| 1 & 3 Phase | AMPS |
|
| ||
| (81.5 lbs.) | 27.8”* |
| ||||
|
|
|
| ||||
|
|
|
| (37.0 kg.) | (373 x 338 x |
| |
|
| 575 |
|
| |||
|
|
|
| 706*)mm |
| ||
|
|
|
|
|
| ||
|
| 60/50 HZ | 300A / 32V / 100% |
|
| *Includes |
|
|
|
|
| Handles |
| ||
|
|
| 1 & 3 Phase |
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
* Overall Length Including Handle, 21.6” (549mm) without handle.
POWER WAVE 355 INPUT CURRENT
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz | Output | Recommended |
|
|
| |||
|
|
|
|
|
|
|
|
|
Voltage | Phases | 300Amps @ | 350Amps @ | Line Cord | Fuse size | Notes | ||
|
| 32Volts(100%) | 34Volts(60%) | AWG |
|
|
|
|
200 | 1 | Not | Not |
| Note 1 |
|
| |
|
| Recommended | Recommended |
|
|
|
|
|
208 | 1 | 76 | 94 | 2 | 125A | Note 2 | ||
230 | 1 | 69 | 85 | 4 | 125A | Note 2 | ||
380 | 1 | Not | Not |
| Note 1 | |||
|
| Recommended | Recommended |
|
|
|
|
|
400 | 1 | Not | Not | Note 1 |
| |||
|
| Recommended | Recommended |
|
|
|
|
|
415 | 1 | 41 | 64 | 6 | 80A | Note 2 | ||
460 | 1 | 36 | 42 | 8 | 70A |
|
|
|
575 | 1 | 31 | 37 | 8 | 50A |
|
|
|
|
|
|
|
|
|
| ||
200 | 3 | 41 | 50 | 6 | 80A | Note 2 | ||
208 | 3 | 39 | 50 | 6 | 80A | Note 2 | ||
230 | 3 | 36 | 42 | 8 | 70A |
|
|
|
380 | 3 | 23 | 28 | 8 | 50A |
|
|
|
400 | 3 | 22 | 27 | 8 | 50A |
|
|
|
415 | 3 | 22 | 26 | 8 | 50A |
|
|
|
460 | 3 | 19 | 23 | 8 | 50A |
|
|
|
575 | 3 | 16 | 18 | 8 | 35A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note 1. Not rated is indicated by
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select The output cable size based upon the following chart.* |
| |||
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated: |
| |||
|
|
|
|
|
DUTY CYCLE | CURRENT | LENGTH UP 200FT.(61m) |
| |
100% | 300 | 1/0 |
| 1/0 |
60% | 350 | 1/0 |
| 2/0 |
|
|
|
|
|
*Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.