F-8

TROUBLESHOOTING & REPAIR

F-8

 

 

 

 

Observe Safety Guidelines

 

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

Auxiliary receptacle is “dead” no

1.

Circuit breaker CB1 (on case

1.

Perform the Auxiliary

 

 

auxiliary voltage.

 

 

front) may have opened. Reset.

 

Transformer Test.

 

 

 

 

2.

Circuit breaker CB3 (in recon-

 

 

 

 

 

 

 

nect area) may have opened.

 

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

 

 

 

3.

On PW 405 models, the circuit

 

 

 

 

 

 

 

breaker

CB4

protects the

 

 

 

 

 

 

 

220VAC

receptacle.

Reset if

 

 

 

 

 

 

 

tripped.

 

 

 

 

 

 

 

 

 

 

 

A fault or error code is displayed.

1. See Fault Code Explanations.

1. See Fault Code Explanations.

 

 

 

 

 

 

 

 

 

 

General degradation of the weld

1.

Check

for feeding

problems,

1.

Perform the Voltage and

 

 

performance.

 

 

bad connections,

excessive

 

Current Calibration

 

 

 

 

 

loops in cabling, etc.

 

 

Procedure.

 

 

 

 

2.

Verify weld mode is correct for

2.

Perform the Current

 

 

 

 

 

processes.

 

 

 

Transducer Test.

 

 

 

 

3.

The power source may require

2.

Perform the Output Diode

 

 

 

 

 

calibration.

 

 

 

Module Test.

 

 

 

 

4.

Check the actual current dis-

5.

The control board may be

 

 

 

 

 

played on the Power Feed 10

 

faulty.

 

 

 

 

 

vs. actual current measured via

 

 

 

 

 

 

 

external meter.

 

 

 

 

 

 

 

 

5.

Check the actual voltage dis-

 

 

 

 

 

 

 

played on the Power Feed 10

 

 

 

 

 

 

 

vs. actual voltage measured via

 

 

 

 

 

 

 

external meter.

 

 

 

 

 

 

 

 

6.

Check the actual WFS displayed

 

 

 

 

 

 

 

on the Power Feed 10 vs. actual

 

 

 

 

 

 

 

WFS measured

via external

 

 

 

 

 

 

 

meter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353(WELD).