TROUBLESHOOTING & REPAIR
POWER BOARD TEST (CONTINUED)
TABLE F.3 – POWER BOARD VOLTAGE CHECKS
CHECK POINT | TEST | CONNECTOR | LEAD NO. OR | NORMAL | |
LOCATION | DESCRIPTION | PLUG PIN NO. | IDENTITY | ACCEPTABLE | |
|
|
|
|
| VOLTAGE |
|
|
|
|
| READING |
POWER BOARD | CHECK 40 VDC | 2 (+) |
| 477 (+) | 38 – 42 VDC |
CONNECTOR | INPUT FROM | 1 |
| 475 |
|
PLUG J41 | DC BUS BOARD | 475 | 477 |
|
|
|
|
|
| ||
POWER BOARD | CHECK +15 | 1 (+) |
| 412 (+) | +15 VDC |
CONNECTOR | VDC SUPPLY FROM | 5 |
| 410 |
|
PLUG J42 | POWER BOARD | 412 |
|
|
|
|
|
|
| ||
|
| 410 |
|
|
|
POWER BOARD | CHECK +5 VDC | 3 (+) |
| 408 (+) | +5 VDC |
CONNECTOR | SUPPLY FROM | 5 | 408 | 410 |
|
PLUG J42 | POWER BOARD |
|
|
|
|
|
| 410 |
|
|
|
POWER BOARD | CHECK | 2 (+) |
| 411 (+) | |
CONNECTOR | SUPPLY FROM | 5 |
| 410 |
|
PLUG J42 | POWER BOARD | 411 |
|
|
|
|
|
|
| ||
|
| 410 |
|
|
|
POWER BOARD | CHECK +5 VDC | 5 (+) |
| 1104 (+) | +5 VDC |
CONNECTOR | ARCLINK SUPPLY | 10 | 1104 | 1103 |
|
PLUG J43 | FROM POWER BOARD |
|
|
|
|
|
|
| 1103 |
|
|
POWER BOARD | CHECK +5 VDC | 4 (+) |
| 406 (+) | +5 VDC |
CONNECTOR | 9 | 406 | 405 |
| |
PLUG J43 | FROM POWER BOARD |
|
|
|
|
|
| 405 |
|
|
|
|
| 3 (+) |
|
|
|
POWER BOARD | CHECK +5 VDC | 403 12 |
| 403 (+) | +5 VDC |
CONNECTOR | SPI SUPPLY FROM |
|
| 401 | |
PLUG J43 | POWER BOARD |
| 401 |
|
|
|
|
|
|
|