Return to Section TOC

Return to Master TOC

F-48

F-48

TROUBLESHOOTING & REPAIR

CONTROL BOARD REMOVAL AND REPLACEMENT (continued)

FIGURE F.17 - CONTROL BOARD LOCATION

Return to Section TOC

Return to Master TOC

STATUS

THERMAL

LINCOLN

ELECTRIC

WARNING

REMOTE

POWER

ON

OFF

Control Board

PROCEDURE

1.Remove input power to the POWER WAVE 355/405.

2.Using a 5/16” nut driver remove the case wrap- around cover.

3.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the control board behind the front panel of the machine. See Figure F.17.

5.Using a 5/16” nut driver remove the two screws from the bottom of the front of the machine. See Figure F.18.

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

FIGURE F.18 CASE FRONT SCREW REMOVAL

STATUS

THERMAL

Phillips Head

 

Phillips Head

 

Screws

Screws

_

+

 

 

 

5/16"

Mounting Screws

POWER WAVE 355/405

Page 90
Image 90
Lincoln Electric SVM159-A service manual Control Board