Section TOC

Master TOC

F-29

F-29

TROUBLESHOOTING & REPAIR

DC BUS BOARD TEST(CONTINUED)

Return to

Return to

6.Check the DC Bus Board input and output voltages according to Table F.4. See Figure F.6 and the Wiring Diagram.

WARNING

ELECTRIC SHOCK can kill.

High voltage is present at the terminals of Capacitor C3 near where testing is to be done.

7.If all the voltages are correct, the DC Bus Board is operating properly.

8.If any of the output voltages are not correct and the input voltage is correct, the DC Bus Board may be faulty.

9.If the input voltage is not correct, check the leads between the DC Bus Board and the Bus Rectifier. See the Wiring Diagram.

10.When finished testing, replace the case wraparound cover.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

TABLE F.4 – DC BUS POWER SUPPLY PC BOARD VOLTAGE TABLE

Positive Meter Probe

Negative Meter Probe

Approximate Voltage

Conditions/Comments

Test Point

Test Point

Reading

 

 

 

 

 

 

Plug P46 – Pin 1

Plug P46 – Pin 3

65

– 75 VDC

Should be same as the

Lead 65

Lead 66

 

 

Bus Rectifier

 

 

 

 

 

 

 

 

Plug P47 – Pin 8(+)

Plug P47 – Pin 1(-)

38.0

– 42.0 VDC

Supply to the Wire

Lead 52

Lead 51

 

 

Feeder Receptacle

 

 

 

 

 

Plug P47 – Pin 3(+)

Plug P47 – Pin 6(-)

38.0

– 42.0 VDC

Supply to Power Board

Lead 477

Lead 475

 

 

 

 

 

 

 

 

POWER WAVE 355/405

Page 71
Image 71
Lincoln Electric SVM159-A service manual Table F.4 DC BUS Power Supply PC Board Voltage Table